TS1600DPS, TS1800DPS - LG Washing Machine Service Manual (repair manual). Page 39

Read LG TS1600DPS / TS1800DPS Service Manual online

39
1. Cautions during the service
■  
Both AC220V and DC power are embedded in the controller assembly output connector, so be careful of the 
electric shock during the disorder diagnosis.(Wear cotton gloves during the work.) 
  When you replace controller in the washer, make sure to check if the power is cut off before the disassembly 
or assembly.
  Always be careful of the static electricity during the handling of the controller assembly, and transport and store 
it in static electricity prevention vinyl bag.
You can check problems of the washer as follows by pressing the start/pause button.
The washer must be empty and the controls must be plugged in and turned off.
2. SVC test mode
■  
How to enter SVC test mode: Power ON, press cold water washing and wash key at the same time to enter 
the test mode.
■  
Every time you press start/pause button, test mode changes, and you can check the operation status.
■  
When you start the test mode, door is locked, and when the test mode ends, door opens.
3. Actions in each test mode
■  
You can check problems of the washer as follows by pressing the start/pause button.
4-3. How to use Test Mode
Step
Mode
Action
Displayed Contents
Remark
t1
Main Version Check
All LEDs are lighted
‘Main VERSION’ and ‘Model 
Option Character’
You can check ‘tE Error’
t2
Display Version check 
and Button check
-
‘Display Version’
-
t3
Water 
Valve 
Check
-
-
Level frequency
(26.7kHz is displayed as 67)
Valve operates until 
23.3kHz, and the power 
is automatically turned 
off at 23.3kHz. (Overflow 
prevention)
A
Cold valve is activated
B
Softener Dispenser and Hot 
Valve are activated
C
Jet Spray Dispenser is activated
t4
Heater 
Check
Heater On
Eye sensor correction group 
value(1~26)
Heating is activated
t5
Alpha 
Check
Carry out alpha
Water discharge starts
Alpha RPM
RPM : 220
On time : 180s
Slope : 30 rpm/sec
t6
Drain 
Check
At water discharge level 
frequency of 26.0kHz, after 50 
sec., it is automatically changed 
to T7.
Before the level frequency 
reaching 26.0kHz, level 
frequency is displayed after 
reaching the longitude data.
-
t7
Load 
sensing
Check
After completing spray 
amount detection 1 time, it is 
automatically changed to t8.
Displays spray amount detection 
result value. 
(Displays Err)
-
t8
Agitate 
Check
Door Lock reset
Pulsator Mode change
Pulsator stirring starts
Displays spray amount detection 
result value. 
(Displays Err)
t9
Spin 
Check
anddE 
Error
Check
Basket Mode change
Spin dry starts
Before 500RPM: current RPM/
500RPM or more: UB value/
Before 500RPM: Max emission 
value/
RSt: UB value
Current RPM is displayed in the 
units of 2 sec.
After reaching the maximum 
RPM, continuous MS 
(40~90rpm) area for 200 sec.
UB No sense
t10
OFF
Power off
-
-