Cap
(Remaining Hose)
Screw
Pump Outlet Hose
Tub Pump Bellows
41
Remove pump outlet hose.
Remove tub pump bellows.
Remove cap (Remaining Hose.)
Disconnect the wiring.
Unscrew 3 screws
Remove the pump.
Unscrew 3 screws fixing the heater protecting cover.
Loosen the M6 heater nut to pull out the heater.
Loosen the M6 heater nuts to pull out the HEATER
ASSEMBLY.
When mounting the HEATER ASSMBLY be sure to
insert the HEART ASSEMBLY into the heater clip on
the bottom of the tub.
Pull it out by holding the thermistor bracket.
If it is pulled by the wire, it may be broken.
When mounting the thermistor again, make sure that it
is got back tight to the rubber.
PUMP
HEATER
THERMISTOR