Read LG GK712EN Service Manual online
20
ERROR SYMPTOM
CAUSE
1
WATER INLET
ERROR
2
IMBALANCE
ERROR
3
DRAIN ERROR
4
OVERFLOW
ERROR
5
SENSOR PRESSURE
S/W ERROR
6
DOOR OPEN
ERROR
7
THERMISTOR
ERROR
Water has not reached to the pre-set level within 4
min. since inlet valve operated, or water has not
reached to the normal level within 25 min.
The appliance is tilted.
Laundry is gathered to one side.
Non-distributable things are put into the drum.
Water has not drained enough within 5 min.
Water is automatically being pumped out because too
much water is in the tub.
The sensor pressure switch is out of order.
The
Start/Pause
button is pressed with the door
open.
The door switch is out of order.
The thermistor is out of order.
■
GK708E / GK708EN
If you press the Start/Pause button when an error in displayed, any error except S/W ERROR will
disappear and the machine will change into pause status.
In case of S/W ERROR
THERMISTER ERROR
DOOR OPEN ERROR
if the error is not
resolved within 20 sec. In the case of other errors, if the error is not resolved within 4 min. power will be
turned off automatically and the error code will blink. But in case of OVER FLOW ERROR , power
will not be turned off.d
turned off automatically and the error code will blink. But in case of OVER FLOW ERROR , power
will not be turned off.d
imbalance
no drain
no inlet
Pre
Main
Door
Lock