Read LG F62A8NDS Service Manual online
27
Is the water coming in
drawer
drawer
continuously?
Replace the
Main PCB
.
After power off for 10 sec. and power on.
Does the water level over reference line
Does the water level over reference line
and Is
not
the water level frequency 26.2Khz ?
Or does
not
the water level over reference line
and is the water level frequency 26.2Khz ?
* Water level frequency
- Press and Hold '
Temp.
' & '
Medic Rinse
'
simultaneously.
Replace the
Inlet Valve
assembly.
YES
If FE is displayed again,
then replace the
then replace the
Pressure Switch
.
If FE is displayed again,
then replace the
then replace the
Main PCB
.
Check the
Air Chamber
and the
Tube
(clogged).
NO
NO
YES
Over Flow Error (FE)
Click on the first or last page to see other F62A8NDS service manuals if exist.