20
7-3. HOW TO CHECK THE WATER LEVEL FREQUENCY
7-4. HOW TO CHECK THE TEMPERATURE OF EACH THERMISTOR
AT OPERATING CONDITION.
Press the
Option1
and
Favorite
button simultaneously.
Press the
Option1
and
Temp.
button simultaneously.
The digits means water level frequency. (10-1kHz)
ex) 241 : Water level frequency = 241 x 10-1kHz
ex) 241 : Water level frequency = 241 x 10-1kHz
24.1 kHz
Thermistor in tub temperature.