F1406TDSRU, F1406TDSRB, F1406TDSR7, F1406TDSR6, F1409TDS - LG Washing Machine Service Manual (repair manual). Page 13

Read LG F1406TDSRU / F1406TDSRB / F1406TDSR7 / F1406TDSR6 / F1409TDS Service Manual online

13
7. TROUBLE SHOOTING
7-1. BEFORE SVC CHECKING
Be careful of electric shock or disconnecting the parts while trouble shooting.
Voltage of each terminal in 220-240V~ and DC while applying an electric current.
7-2. QC TEST MODE
1 Pressing Rinse and Steam Wash button simultaneously.
7-3. HOW TO CHECK THE WATER LEVEL FREQUENCY
Press the Rinse and Medic Rinse button simultaneously.
2 Press the Power      button, while the above condition.
3 Press the Start/Pause button as follows.
None 
1 time 
2 times 
3 times 
4 times 
5 times 
6 times 
7 times 
8 times 
9 times 
10 times 
11 times 
12 times 
13 times 
14 times 
15 times
Turns on all lamps and locks the door.
Tumble clockwise. 
Low speed Spin. 
High speed Spin. 
Inlet valve for prewash turns on. 
Inlet valve for main wash turns on. 
Inlet valve for hot water turns on. 
Inlet valve for steam turns on. 
Inlet valve for bleach turns on. 
Tumble counterclockwise. 
Heater turns on for 3 sec. 
Circulation pump turns on. 
Drain pump turns on. 
Water level Sensor for Steam  
Steam Heater turns on for 1.2 sec. 
Off
rpm (42~50)
rpm (55~65)
rpm (125~155)
Water level frequency (25~65)
Water level frequency (25~65)
Water level frequency (25~65)
Water level frequency (25~65)
Water level frequency (25~65)
rpm (42~50)
Water temperature
Water level frequency (25~65)
Water level frequency (25~65)
Water level frequency of TSG (0~255)
TSG temperature
-
The digits indicate the water level frequency.
So, for example a display indicating 058:
a Water level frequency of 20+(58 x 0.1)= 25.8 kHz
Number of times the
Start/Pause button is pressed
Check Point
Display Status
QC TEST MODE
VIEWING DATA
045
000
000
055
000
061
028
028
000
000
029
000
064
048
000
000
222
290
7-4. HOW TO KNOW TO TEMPERATURE OF EACH THERMISTOR AT OPERATING CONDITION.
Press the Rinse and Medic Rinse button simultaneously.
Thermistor in tub temperature.
VIEWING DATA
045
000
000
055
000
061
028
028
000
000
029
000
064
048
000
000
222
290
Page of 36
Display

Click on the first or last page to see other F1406TDSRU / F1406TDSRB / F1406TDSR7 / F1406TDSR6 / F1409TDS service manuals if exist.