Read LG F1296ND4 Service Manual online
3
7
INLET VALVE
1
Disconnect the wiring receptacle.
2
Unscrew 2 screws from the back.
• Rating : 220/240V 50/60Hz
• Resistant : 3.5~4.5kΩ
When reconnecting the connector
LOWER COVER
Open the lower cover cap by using coin and
pull out the lower cover to the arrow direction
after a screw is unscrewed.
VALVE #1 (MAIN)
VALVE #2 (PRE)
VALVE #3 (HOT)
White / Black - Black
Gray / White - Black
Blue / Red - Black
DOOR
1
Open the door completely.
2
Remove the two screws from the hinge.
When removing the door assembly, it is
necessary to hold the bracket that is inner
of the cabinet cover.
necessary to hold the bracket that is inner
of the cabinet cover.
3
1
2