Read LG F1280CDP2 / F1280CDP25 Service Manual online
43
• V ~ U (8~11
Ω)
• U ~ W (8~11
Ω)
• W ~ V (8~11
Ω)
Motor Stator
U V W
Hall Sensor
Ha
Hb
Common
• Common ~ Ha (5~15k
Ω)
• Common ~ Hb (5~15k
Ω)
1 Remove the back cover.
2 After loosening the bolt, Rotor, pull out the
2 After loosening the bolt, Rotor, pull out the
rotor.
1 Remove the 6 bolt from the stator.
2 Disconnect the 2 connectors.
2 Disconnect the 2 connectors.
1 Remove the hinges (Damper) at the Tub.
3 The hinge at the base is pulled off.
(To arrow direction)
2 The Hinge(Damper) at the base is pulled off
pressing on the snaps at the sharp end.
ROTOR ASSEMBLY, STATOR ASSEMBLY, FRICTION DAMPER