Read LG F1273QDP Service Manual online
31
Is the water coming in
drawer continuously?
Replace the
Main PCB
.
After power off for 10 sec. and power on.
Does the water level over reference line and Is
not
the water level frequency 25.5Khz or 26.1Khz ?
Or does
not
the water level over reference line and is the water level frequency 25.5Khz or 26.1Khz?
F1*22TD
Press
“
Temp
.” and “
Medic Rinse
”
F1*20TD
Press “
Intensive
”
Replace the
Inlet Valve
assembly.
YES
If FE is displayed again,
then replace the
Pressure Switch
.
If FE is displayed again,
then replace the
Main PCB
.
Check the
Air Chamber
and the
Tube
(clogged).
NO
NO
YES
Over Flow Error (FE)