Read LG F1255FD Service Manual online
14
Be careful of electric shock or disconnecting the parts while trouble shooting.
The voltage of each terminal is 220-240V AC and DC when the unit is plugged in.
The voltage of each terminal is 220-240V AC and DC when the unit is plugged in.
7. TROUBLE SHOOTING
7-1.BEFORE SVC SERVICE
7-2. QC TEST MODE.
1. Press the RINSE and SPIN buttons simultaneously.
2. Press the Power button, while the above condition. Then buzzer will sound twice.
3. Press the Start/Pause button repeatedly to cycle through the test modes.
2. Press the Power button, while the above condition. Then buzzer will sound twice.
3. Press the Start/Pause button repeatedly to cycle through the test modes.
The washer must be empty and the controls must be in the off state.
The digits indicate the water level frequency ( x.1 kHz ).
So, for example a display indicating 241: a Water level frequency of 241 x.1 kHz
= 24.1 kHz
None
1 time
2 times
3 times
4 times
5 times
6 times
7 times
8 times
9 times
10 times
11 times
12 times
13 times
14 times
Turns on all lamps and locks the door.
Tumble clockwise
Low speed Spin.
High speed Spin.
Inlet valve for prewash turns on.
Inlet valve for main wash turns on.
Inlet valve for hot water turns on.
Inlet valve for steam turns on.
Tumble counterclockwise
Heater turns on for 3 sec.
Circulation pump turns on.
Drain pump turns on.
Water level inside the steam generator
Heater turns on for 2 sec
Power off and unlock the door.
rpm (40~50)
rpm
rpm
Water level frequency (25~65)
Water level frequency (25~65)
Water level frequency (25~65)
Water level frequency (25~65)
rpm (40~50)
Water temperature
Water level frequency (25~65)
Water level frequency (25~65)
Water level frequency(0~255)
Temperature inside the steam generator
Turn off all lamps.
Number of times the
Start/Pause button is pressed
Check Point
Display Status
Press the Spin and Rinse button simultaneously.
7-3.HOW TO CHECK THE WATER LEVEL FREQUENCY
Click on the first or last page to see other F1255FD service manuals if exist.