17
7. TROUBLESHOOTING
7-1. BEFORE PERFORMING SERVICE
7-2. LOAD TEST MODE
1 F**89Q/TD / F**92Q/TD : Press and Hold ‘
Temp.
’ & ‘
Spin
’ buttons and then press ‘
Power
’ button.
7-3. HOW TO KNOW THE WATER LEVEL FREQUENCY
F**89Q/TD / F**92Q/TD : Press and Hold ‘ Spin ’ & ‘Pre Wash ’ buttons simultaneously.
2 The washer must be empty and the controls must be in the o ff state.
3 Press Power with above two buttons pressed and then buzzer will sound.
4 Press the Start/Pause button repeatedly to cycle through the te st modes
3 Press Power with above two buttons pressed and then buzzer will sound.
4 Press the Start/Pause button repeatedly to cycle through the te st modes
1
2
3
4
5
6
2
3
4
5
6
None
1 time
2 times
3 times
3 times
4 times
5 times
6 times
7 times
8 times
9 times
7 times
8 times
9 times
10 times
All lamp s turn on
Clockwise
Clockwise
wash (right)
Low speed Spin
High speed Spin
High speed Spin
Inlet valve for pre-wash operation
Inlet valve for main-wash operation
Hot inlet valve in case of hot water fill
Counterclockwise wash (left)
A Heater is in operation for 3 sec.
Draining pump operation
Counterclockwise wash (left)
A Heater is in operation for 3 sec.
Draining pump operation
Auto off operation
Motor rpm (About 47)
Motor rpm (About 590~650)
Motor rpm(About 950~1050) :F80**QDT(P)2(A)(0~9)
Motor rpm(About 1100~1250) :F10/12**QDT(P)2(A)(0~9)
Motor rpm(About 1330~1400) :F14**QDT(P)2(A)(0~9)
Water level frequency (255->299)
Motor rpm (About 590~650)
Motor rpm(About 950~1050) :F80**QDT(P)2(A)(0~9)
Motor rpm(About 1100~1250) :F10/12**QDT(P)2(A)(0~9)
Motor rpm(About 1330~1400) :F14**QDT(P)2(A)(0~9)
Water level frequency (255->299)
Water level frequency (255->299)
Water level frequency (255->299)
Motor rpm (About 47)
Water Temperature
Water level frequency
Motor rpm (About 47)
Water Temperature
Water level frequency
The digits means water level frequency (10
-1
kHz)
ex) 241 : Water level frequenc y = 241 X 10
-1
kHz
= 24.1kHz
Pressing number of
[Start/Pause] button
Checking Point
Display Status
F**89Q/TD / F**92Q/TD
Click on the first or last page to see other F1092QDT2 / F1092QDT25 / F1092QDTA5 service manuals if exist.