5.2 EEPROM DATA READ
(1) Signal Table
(2) Command Set
* Purpose : To read the appointment Address of E
2
PROM by
128(80h)-byte
5.3. E
2
PROM Data Write
(1) Signal Table
LEN : 84h+Bytes
CMD : 8Eh
ADH : E
CMD : 8Eh
ADH : E
2
PROM Slave Address(A0,A2,A4,A6,A8), Not
00h(Reserved by BufferToEEPROM)
ADL : E
2
PROM Sub Address(00~FF)
Data : Write data
(2) Command Set
* Purpose
1) EDID write : 16-byte by 16-byte, 8 order (128-byte)
write(TO “00 – 7F” of “EEPROM Page A4”).
2) FOS Default write : 16-mode data (HFh, HFl, VF, STD,
HP, VP, Clk, ClkPh, PhFine) write.
3) Random Data write : write the appointment Address of
E
2
PROM.
5.4. VRAM Read
1) Send CMD(70h) to read Video RAM value from MICOM
And save its value to 128-Bytes Buffer.(Common Buffer for
the use of EDID)
the use of EDID)
2) Delay 500ms. (Time to Wait and Read Video RAM from
MICOM)
3) Be transmitted the contents of MICOM’s 128-bytes Buffer to
PC. (128th Data is the CheckSum of 127-bytes data :
That’s OK if the value of adding 128-bytes Data is Zero)
That’s OK if the value of adding 128-bytes Data is Zero)
- 12 -
128 Bytes
Delay 100ms
Data 128
EEPROM READ
E7
A0
0
0-Page 0~7F Read
80
0-Page 80~FF Read
A2
0
1-Page 0~7F Read
80
1-Page 80~FF Read
A4
0
2-Page 0~7F Read
80
2-Page 80~FF Read
A6
0
3-Page 0~7F Read
80
3-Page 80~FF Read
Adjustment contents CMD(hex) ADH(hex) ADL(hex)
Details
EEPROM WRITE
E8
94
16-Byte Write
84+n
n-byte Write
Adjustment contents
CMD(hex)
ADH(hex)
Details