12. AREA OPTION
12-1. Using DFT(Auto)
PC (for communication through RS-232C) ==> UART Baud
rate : 115200 bps
Command : ah 00 00 DATA(Area Number(hexadecimal))
rate : 115200 bps
Command : ah 00 00 DATA(Area Number(hexadecimal))
12-2. Setting Manual
Press ADJ R/C In-start key and select 1.AREA OPTION,
Select Model Number by using
Select Model Number by using
F
/
G
(VOL +/-) in accordance
with destination
12-3. Outgoing condition Configuration
- After all function test, press IN-STOP Key by SVC Remote
controller. And Make Ship Condition.
- When pressing IN-STOP key by SVC remocon, Red LED
are blinked alternatively. And then Automatically turn off.
(Must not AC power OFF during blinking)
(Must not AC power OFF during blinking)
Confirm whether is normal or not when between power
board's ac block and GND is impacked on 1.5kV(dc) or
2.2kV(dc) for one second
board's ac block and GND is impacked on 1.5kV(dc) or
2.2kV(dc) for one second
13. Default Service option.
13-1. ADC-Set
.
V
R-Gain adjustment Value (default 128)
V
G-Gain adjustment Value (default 128)
V
B-Gain adjustment Value (default 128)
V
R-Offset adjustment Value (default 64)
V
G-Offset adjustment Value (default 64)
V
B-Offset adjustment Value (default 64)
13-2. White balance.
CENTER (DEFAULT)
MAX
Cool
Mid
Warm
R Gain
184
192
192
255
G Gain
189
184
150
255
B Gain
192
161
128
255
R Cut
128
128
128
255
G Cut
128
128
128
255
B Cut
128
128
128
255