(2) Va adjustment (refer fig.1)                                               
1) After receiving 100% Full White Pattern, HEAT RUN.
2) Connect + terminal of D.M.M. to Va pin of
P812(42”:P811), connect -terminal to GND pin of
P811(42”:P812).
3) After turning VR502,voltage of D.M.M adjustment as
same as Va voltage which on label of panel left/top
(deviation; ±0.5V)
11. Default Service option.
11-1. ADC-Set
.
V
R-Gain adjustment Value (default  128)
V
G-Gain adjustment Value (default  128)
V
B-Gain adjustment Value (default  128)
V
R-Offset adjustment Value (default  128)
V
G-Offset adjustment Value (default  128)
V
B-Offset adjustment Value (default  128)
11-2. White balance. Value.
11-3. Temperature Threshold
V
Threshold Down Low
20
V
Threshold Up Low
23
V
Threshold Down High 70
V
Threshold Up High
75
12. USB DOWNLOAD 
(*.epk file download)
V
Put the USB Stick to the USB socket
V
Press Menu key, and move OPTION 
V
Press “FAV” Press 7 times.
V
Select download file (epk file)
V
After download is finished, remove the USB stick.
Press “IN-START” key of ADJ remote control, check the
S/W version.
- After downloading, have to adjust TOOL OPTION again.
1. Push "IN-START" key in service remote controller.
2. Select "Tool Option 1" and Push “OK” button.
3. Punch in the number. (Each of models has their number.)
4. Completed selecting Tool option.
- 12 -
CENTER (DEFAULT)
Cool
Mid
Warm
R Gain
192
192
192
G Gain
192
192
192
B Gain
192
192
192
R Cut
64 
64
64  
G Cut
64
64
64
B Cut
64
64
64
Model
60PT100C-WA
60PT200C- WA
Module
60C2
60C2
Tool Option1
49440
49440
Tool Option1
16902
16902
Tool Option1
128
128
Tool Option1
0
0
Tool Option1
65
64