60PK940-UF, 60PK950-UA (CHASSIS:PU02A) - LG TV Service Manual (repair manual). Page 8

Read LG 60PK940-UF / 60PK950-UA (CHASSIS:PU02A) Service Manual online

- 8 -
ADJUSTMENT INSTRUCTION
1. Application Range
This  spec.  sheet  applies  to  PU02A  Chassis  applied  PDP  TV
all models manufactured in TV factory.
2. Specification
(1) Because this is not a hot chassis, it is not necessary to use
an  isolation  transformer.  However,  the  use  of  isolation
transformer will help protect test instrument.
(2) Adjustment must be done in the correct order.
(3) The adjustment must be performed in the circumstance of
25 
c
C  ± 5  cC  of  temperature  and  65  %  ± 10  %  of  relative
humidity if there is no specific designation.
(4) The input voltage of the receiver must keep 100 V - 240 V,
50 / 60 Hz.
(5) The receiver must be operated for about 5 minutes prior to
the adjustment when module is in the circumstance of over
15 cC
- In case of keeping module is in the circumstance of 0 cC,
it should be placed in the circumstance of above 15 cC for
2 hours 
- In case of keeping module is in the circumstance of below
-20 cC, it should be placed in the circumstance of above
15 cC for 3 hours.
Caution) When still image is displayed for a period of 20 minutes
or longer (especially where W/B scale is strong.  Digital
pattern  13ch  and/or  Cross  hatch  pattern  09ch),  there
can some afterimage in the black level area.
3. Adjustment items
3-1. Board-level adjustment
- Mac address and Idfile(ESN) Download
- Adjust 480i Comp1 adj.
- Adjust 1080p Comp1 adj.
- Adjust 1920*1080 RGB adj.
- EDID/DDC download 
Above  adjustment  items  can  be  also  performed  in  Final
Assembly if needed.  Both Board-level and Final assembly
adjustment  items  can  be  check  using  In-Start  Menu  1.
Adjust Check.
3-2. Final assembly adjustment
- White Balance adjustment
- RS-232C functionality check
- Factory Option setting per destination
- Ship-out mode setting (In-Stop)
3-3. Etc.
- Ship-out mode
- Service Option Default
- USB Download(S/W Update, Option)
4. MAC Address and ESN Key Write
4-1. Equipment & Condition
- Play file: Serial.exe
- MAC Address edit
- Input Start / End MAC address
4-2. Download method
(1) Communication Prot connection
Connect: PCBA Jig-> RS-232C Port== PC-> RS-232C Port
(2) MAC Address Download
- Com 1,2,3,4 and 115200(Baudrate)
- Port connection button click(1)
- Load button click(2) for MAC Address write.
- Start MAC Address write button(3)
- Check the OK Or NG 
(3) Input the ESN Key 
- download Model sending Key file
- input by 1 by SET so as not to be duplicated
Page of 64
Display