60PK940-UF, 60PK950-UA (CHASSIS:PU02A) - LG TV Service Manual (repair manual). Page 14

Read LG 60PK940-UF / 60PK950-UA (CHASSIS:PU02A) Service Manual online

V
Adj. condition and cautionary items
(1) Lighting condition in surrounding area
Surrounding  lighting  should  be  lower  than  10  lux.    Try
to isolate adj. area into dark surrounding.
(2) Probe location
- PDP : Color  Analyzer  (CA-100,  CA-100+,  CA210)
probe should be firmly attached to the Module
- LCD : Color Analyzer (CA-210) probe should be within
10cm  and  perpendicular  of  the  module  surface
(80°~ 100°)
- In  case  of  LCD,  B/L  on  should  be  checked  using  no
signal or Full white Pattern
8-7. Reference  (White  Balance  adj.
coordinate and color temperature)
Standard color coordinate and temperature using CS-1000
Luminance: Full white 216 Gray
Standard  color  coordinate  and  temperature  using  CA-210(CH
10)
- Gain color coordinate
Pattern : Full white 216 Gray
- Offset color coordinate : Only THX model
Pattern : Full white 50 Gray 
Luminance : 5 ± 4 cd
9. Option selection per country
9-1. Overview
Applied  model:  PU02A  Chassis  applied  USA  Model(Not
Canada, Mexico)
9-2. Method
(1) Press ADJ key on the Adj. R/C, then select Country Group
Menu
(2) Depending  on  destination,  select  KR  or  US,  then  on  the
lower option, select US, CA, MX.  Selection is done using
+, - KEY
9-3. Ship-out (Default) mode check (Instop)
O
After final inspection, press In-Stop key of the Adj. R/C and
check that the unit goes to Stand-by mode. 
9-4. POWER  Supply  Unit  PCB  Ass'y  Va/Vs
Voltage adjustment
.
[ Caution ] 
Both Vs and Va voltage adjustment are necessary.
(1) Model name: 50/60PK750-UA, 50/60PK950-UA 
(2) Va/Vs Adjustment Procedure
1) Connect  positive(+)  terminal  of  DMM  to  Vs/Va  pin,
connect negative(-) terminal to GND.
2) Turning  ‘  Vs/Va  ’  and  adjust  Vs/Va  voltages  to  a  value
which is written on a right/top label of a module.
( deviation ; ± 0.5V)
[ Caution ] 
Each  Power  Supply  Unit  PCB  assembly  must  be  checked  by
check JIG set.
(Because  power  PCB  Ass°Øy  damages  to  PDP  Module,
especially be careful)
[Caution]
Set up "RF mode(noise)" before a voltage adjustment.
10. Service Option Default
- 14 -
Model
Tool          Tool        Tool        Tool       Tool
option1   option2    option3   option4   option5
50PK750-UA
36896
55844
35280
4428
0
60PK750-UA
49184
55844
35280
4428
0
Page of 64