Read LG 60PK550C-TA (CHASSIS:PP01ABC) Service Manual online
- 4 -
SPECIFICATION
NOTE : Specifications and others are subject to change without notice for improvement.
V
Application Range
This spec is applied to the PLASMA TV used
H6 Chassis.
V
Specification
Each part is tested as below without special appointment.
(1) Temperature : 25 °C ± 5 °C (77 °F ± 9 °F), CST : 40 ± 5
(2) Relative Humidity: 65 % ± 10 %
(3) Power Voltage: Standard Input voltage (100 V - 240 V ~, 50 / 60 Hz)
(1) Temperature : 25 °C ± 5 °C (77 °F ± 9 °F), CST : 40 ± 5
(2) Relative Humidity: 65 % ± 10 %
(3) Power Voltage: Standard Input voltage (100 V - 240 V ~, 50 / 60 Hz)
* Standard Voltage of each product is marked by models.
(4) Specification and performance of each parts are followed each drawing and specification by part number in accordance with
BOM.
(5) The receiver must be operated for about 20 minutes prior to the adjustment.
V
Test Method
(1) Performance : LGE TV test method followed.
(2) Demanded other specification
(2) Demanded other specification
Safety : CE, IEC specification
EMC : CE, IEC
EMC : CE, IEC
V
Module Specification
(1)
60” HD
Display Screen Device
Aspect Ratio
PDP Module
Operating Environment
Storage Environment
Input Voltage
1
2
3
4
5
6
No
Item
Specification
Remark
60
60 inch16:9 Color Display Module
16:9
PDP
60R1####,
RGB Closed(Well) Type, Glass Filter(38 %)
Pixel Format: 1365 horiz. By 768 ver.
1) Temp. : 0 deg ~ 40 deg
2) Humidity : 20 % ~ 80 %
3) Temp. : -
10 deg ~ 60 deg
4) Humidity : 10 % ~ 90 %
AC 100 V - 240 V ~, 50 / 60 Hz
PDP
LGE SPEC.
Maker
:SANKEN