Read LG 60LN5400 (CHASSIS:LA31F) Service Manual online
- 14 -
5.4. 3D Module inspection
5.4.1. Test equipment
(1) Pattern Generator MSHG-600 or MSPG-6100 (HDMI 1.4
support)
(2) Pattern: HDMI mode (model No. 872, pattern No. 83)
5.4.2. Test method
(1) Start 3D pattern inspection
Fig.1 <model No. 872, pattern No. 83>
(2) check the 3D patterm with 3D FPR Glasses or L/R Film.
(3) If 3D Module is correctly worked, The 3D FPR Glasses is
change Color. Left is Red. Right is Blue.
5.5. Ship-out mode check (In-stop)
- After final inspection, press In-Stop key of the Adj. R/C and
check that the unit goes to Stand-by mode
6. GND and HI-POT Test
6.1. GND & HI-POT auto-check preparation
(1) Check the POWER CABLE and SIGNAL CABE insertion
condition
6.2. GND & HI-POT auto-check
(1) Pallet moves in the station. (POWER CORD / AV CORD is
tightly inserted)
(2) Connect the AV JACK Tester.
(3) Controller (GWS103-4) on.
(4) GND Test (Auto)
- If Test is failed, Buzzer operates.
- If Test is passed, execute next process (Hi-pot test).
(Remove A/V CORD from A/V JACK BOX)
(5) HI-POT test (Auto)
- If Test is failed, Buzzer operates.
- If Test is passed, GOOD Lamp on and move to next
process automatically
6.3. Checkpoint
(1) Test voltage
- GND: 1.5KV/min at 100mA
- SIGNAL: 3KV/min at 100mA
(2) TEST time: 1 second
(3) TEST POINT
- GND Test = POWER CORD GND and SIGNAL CABLE
GND.
- Hi-pot Test = POWER CORD GND and LIVE & NEUTRAL.
(4) LEAKAGE CURRENT: At 0.5mArms