60GA6400-UD (CHASSIS:LA37G) - LG TV Service Manual (repair manual). Page 17

Read LG 60GA6400-UD (CHASSIS:LA37G) Service Manual online

- 17 -
4.5. Option selection per country
4.5.1. Overview
(1)  Press ADJ  key  on  the Adj.  R/C,  and  then  select  Country 
Group Menu.
(2)  Depending  on  destination,  select  KR  or  US,  then  on  the 
lower Country option, select US, CA, MX. Selection is done 
using +, - KEY
4.6. Tool Option Inspection
▪ Method: Press Adj. key on the Adj. R/C, then select Tool option. 
Model
Tool 1
Tool 2
Tool 3
Tool 4
Tool 5
Tool 6 Tool 7
47GA6400-UD 33207
8723
30512 13356 18441
1322
13963
42GA6400-UD 33206
8723
30512 13356 18441
1322
13963
4.7. Local Dimming Inspection (Optional)
(1)  Press  ‘TILT”  key  of  the  Adj.  R/C  and  check  moving 
patterns. The black bar patterns moves from top to bottom.
      If a local dimming function does not work, a whole screen 
shows full white
4.8. Ship-out mode check (In-stop)
▪  After final inspection, press In-Stop key of the Adj. R/C and 
check that the unit goes to Stand-by mode.
▪ After final inspection, Always turn on the Mechanical S/W.
4.9. WIFI MAC ADDRESS CHECK
a. Using RS232
Command
Set ACK
Transmission
[A][l][][Set ID][][20][Cr]
[O][K][x]  or  [N][G]
b. check the menu on in-start
Note that there are Wi-Fi MAC and MAC address.
Wi-Fi MAC is used for wireless network and MAC address is used 
for wired network
5.1. Method
   - Check that Power Cord is fully inserted to the SET.
     (If loose, re-insert)
    -  Unit  fully  inserted  Power  cord; Antenna  cable  and A/V 
arrive to the auto-check process. 
    - Connect D-terminal to AV JACK TESTER
    - Auto CONTROLLER (GWS103-4) ON
    - Perform GND TEST
    - If NG, Buzzer will sound to inform the operator.
    - If OK, changeover to I/P check automatically.
      (Remove CORD, A/V form AV JACK BOX)
    - Perform I/P test
    - If NG, Buzzer will sound to inform the operator.
    -  If OK, Good lamp will lit up and the stopper will allow the 
pallet to move on to next process.
5.2. Checkpoint
(1) Test voltage
    - GND: 1.5KV/min at 100mA
    - SIGNAL: 3KV/min at 100mA
(2) TEST time: 1 second
(3) TEST POINT
    -  GND  Test  =  POWER  CORD  GND  and  SIGNAL  CABLE 
GND.
    - Hi-pot Test = POWER CORD GND and LIVE & NEUTRAL.
(4) LEAKAGE CURRENT: At 0.5mArms
6. EYE-Q Operation check
Step 1) Turn on the TV..
Step 2)  Press  'EYE  button'  on  the  adjustment  remote-
controller.
Step 3)  Cover  'Eye  Q  sensor'  on  the  front  of  set  with  your 
hands, hold it for 6 seconds.
Step 4)  Check "the Sensor Data" on the screen, make certain 
that  Data  is  below  10.  If  Data  isn’t  below  10  in  6 
seconds,  Eye  Q  sensor  would  be  bad.  You  should 
change Eye Q sensor.
Step 5)  Uncover  your hands  from Eye Q sensor, hold  it for 6 
seconds.
Step 6)  Check  "Back  Light(xxx)"  on  the  screen,  check  data 
increase . You should change Eye Q sensor. 
 
<Step 2>
<Step 5>
<Step 6>
<Step 3>
<Step 4>
Page of 127
Display

Click on the first or last page to see other 60GA6400-UD (CHASSIS:LA37G) service manuals if exist.