55LN5400 (CHASSIS:LT36B) - LG TV Service Manual (repair manual). Page 12

Read LG 55LN5400 (CHASSIS:LT36B) Service Manual online

- 12 -
4. Total Assembly line process
4.1. Adjustment Preparation
■ W/B Equipment condition
    CA210 :  CH14, Test signal : Inner pattern (80IRE) – in case of 
LED back light
■  Above 5 minutes H/run in the inner pattern. (“power on” key of 
adjust remote control)
► The spec of color temperature and coordinate
Model
Mode
Color Temp
Color coordinate
Remark
All
Cool (C50)
13,000k
x = 0.271 (±0.002)
y = 0.270 (±0.002)
 Test signal
 - Inner pattern for W/B adjust
 - External white pattern
   (80IRE, 204gray)
Medium (0)
9,300k
x = 0.286 (±0.002)
y = 0.289 (±0.002)
Warm (W50)
6,500k
x = 0.313 (±0.002)
y = 0.329 (±0.002)
► CA210 : CH 14, Test signal : Inner pattern (80IRE)
-  Standard  color  coordinate  and  temperature  using  CA-1000  (by 
H/R time)
▪ Normal line
model:  (normal line)LN5xxx, LA6xxx, LA7xxx, LA8xxx 
H/R Time(Min)
Cool
Medium
Warm
x
y
x
x
y
x
271
270
286
289
313
329
1
0-2
283 
287 
298 
306 
322
342
2
3-5
282 
285 
297 
304 
321
340
3
6-9
281 
284 
296 
303 
320
339
4
10-19
279 
281 
294 
300 
318
336
5
20-35
277 
277 
292 
296 
316
332
6
36-49
275 
274 
290 
293 
314
329
7
50-79
273 
272 
288 
291 
312
327
8
80-119
272 
271 
287 
290 
311
326
9
Over 120
271 
270 
286 
289 
310
325
▪ Aging chamber line
model:  (aging chamber)LN5xxx, LA6xxx, LA7xxx, LA8xxx
H/R Time(Min)
Cool
Medium
Warm
x
y
x
x
y
x
271
270
286
289
313
329
1
0-5
282 
285 
297 
304 
321
340
2
6-10
278 
280 
293 
299 
317 
335 
3
11-20
275 
275 
290 
294 
314 
330 
4
21-30
272 
272 
287 
291 
311 
327 
5
31-40
269 
269 
284 
288 
308 
324 
6
41-50
268 
267 
283 
286 
307 
322 
7
51-80
267 
266 
282 
285 
306 
321 
8
81-119
266 
264 
281 
283 
305 
319 
9
Over 120
265 
263 
280 
282 
304 
318 
  Connecting picture of the measuring instrument 
     (On Automatic control)
Inside PATTERN is used when W/B is controlled. Connect to 
auto controller or push Adjustment R/C POWER-ON -> Enter 
the mode of White-Balance, the pattern will come out.
 Auto-control interface and directions
(1)  Adjust  in  the  place  where  the  influx  of  light  like  floodlight 
around is blocked. (Illumination is less than 10ux).
(2)  Adhere closely  the Color Analyzer ( CA210 ) to the module 
less  than  10cm  distance,  keep  it  with  the  surface  of  the 
Module and Color Analyzer’s Prove vertically.(80~100°).
(3) Aging time
-  After  aging  start,  keep  the  power  on  (no  suspension  of 
power supply) and heat-run over 5 minutes.
-  Using ‘no signal’ or ‘full white pattern’ or the others, check 
the back light on.
● Auto adjustment Map(RS-232C)
   RS-232C COMMAND
   [ CMD    ID    DATA ]    
       Wb     00       00       White Balance Start
       Wb     00       ff        White Balance End  
RS-232C COMMAND
[CMD ID DATA]
MIN
CENTER
(DEFAULT)
MAX
Cool
Mid
Warm
Cool
Mid
Warm
R Gain
jg
Ja
jd
00
172
192
192
192
G Gain
jh
Jb
je
00
172
192
192
192
B Gain
ji
Jc
jf
00
192
192
172
192
R Cut
64
64
64
128
G Cut
64
64
64
128
B Cut
64
64
64
128
Page of 77
Display