- 10 -
7-1. COMPONENT input ADC (SD / HD), 
RGB input ADC
(1) Press  ADJ  key  on  R/C  for  adjustment.  Need  not  convert
input mode.
(2) Enter Password number. The value of Password is “0 0 0
0”.
(3) Select “0. ADC calibration” by using 
D
/
E
(CH +/-) and press
ENTER(
V
).
(4) Start  ADC  adjustment  by  using 
F
/
G
(VOL  +/-)  or  press
ENTER(
V
).
(5) Both  component  and  RGB  ADC  adjustment  are  executed
automatically 
When ADC adjustment is finished, this OSD appear.
Notice : After All mode check, set the Speaker Volume “0”.
Caution : Don’t Press the Power Key on Remote Controller.
Just AC Power Off. ( Not DC off )
Notice : From this sentence, All working is mass production.
8. POWER PCB Assy Voltage
Adjustment
(Vs voltage Adjustment)
8-1. Test Equipment:
D.M.M 1EA
8-2. Connection Diagram for Measuring
Refer to (Fig. 4)
8-3. Adjustment Method 
(1) Vs Adjustment
1) Connect  +  terminal  of  D.  M..M.  to  Vs  pin  of  P811,
connect -terminal to GND pin of P811.
2) After  turning  VR901,  voltage  of  D.M.M  adjustment  as
same as Vs voltage which on label of panel right/top
( deviation ; ±0.5V)
(2) Va Adjustment
1) Connect  +  terminal  of  D.  M..M.  to  Va  pin  of  P811,
connect -terminal to GND pin of P811.
2) After  turning  VR502,  voltage  of  D.M.M  adjustment  as
same as Va voltage which on label of panel right/top  
( deviation ; ± 0.5 V)
8-4. Adjustment of Area option.
(1) Area Option Adjustment following BOM 
(Including SKD models )
Tool Option
Area Option
Option 1
Option 2
Option 3 ( Available for EU & Non EU model )
* Profile : Must  be  changed  the  option  value  because  being
different with some setting value depend on module,
inch and market
* Equipment : Adjustment Remote Controller
1) Push the IN-START key in the Adjust R/C.
2) Enter Password number. The value of Password is “0 0
0 0”.
3) Input the Area Option Number that was specified in the
BOM, into the Shipping area.
4) Select  “Area  Option”  by  using 
D
/
E
(CH+/-)  key,  and
press the number key(0~9) consecutively
ex) If  the  value  of  Area  Option  40,  input  the  data  using
number key “40” (Fig. 3)
Caution: 
- Although  it  is  SKD  model,  adjust  area  option  in  SET
assemmbly process.
- Don’t  Push  “IN-STOP”  key  after  PCB  assembly
adjustment.
9. Adjustment of White Balance
9-1. Required Equipment
(1) Remote controller for adjustment 
(2) Color  Analyzer  (  CS-1000,  CA-100,100+,CA-210  or  same
produc : CH 10 (PDP) 
lease  adjust  CA-210,  CA-100+  by  CS-1000  before
measuring
(3) Auto W/B adjustment instrument(only for Auto adjustment)
(Fig. 4)
..
Page of 33
Display

Click on the first or last page to see other 50PT250R-TA (CHASSIS:PP11K) service manuals if exist.