Read LG 50PM670T-ZA (CHASSIS:PD22C) Service Manual online
- 6 -
ADJUSTMENT INSTRUCTION
1. Application Range
This spec. sheet applies to PD22C chassis applied PDP TV
all models manufactured in TV factory.
2. Specification
(1) Because this is not a hot chassis, it is not necessary to
use an isolation transformer. However, the use of isolation
transformer will help protect test instrument.
(2) Adjustment must be done in the correct order.
(3) The adjustment must be performed in the circumstance of
25 °C ± 5 °C of temperature and 65±10% of relative
humidity if there is no specific designation.
(4) The input voltage of the receiver must keep 100~240V,
50/60Hz.
(5) The receiver must be operated for about 5 minutes prior to
the adjustment when module is in the circumstance of over
15 °C
- In case of keeping module is in the circumstance of 0°C, it
should be placed in the circumstance of above 15°C for 2
hours
- In case of keeping module is in the circumstance of below
-20 °C, it should be placed in the circumstance of above 15
°C for 3 hours,.
■ After RGB Full White in HEAT-RUN Mode, the receiver must
be operated prior to the adjustment.
■ Enter into HEAT-RUN MODE
1) Press the POWER ON KEY on R/C for adjustment.
2) OSD display and screen display PATTERN MODE.
● Set is activated HEAT run without signal generator in this
mode.
● Single color pattern ( WHITE ) of HEAT RUN MODE uses to
check panel.
● Caution : If you turn on a still screen more than 20 minutes
(Especially digital pattern, cross hatch pattern), an
after image may be occur in the black level part of
the screen.
3. PCB Assembly adjustment
* Caution : Using ‘power on’ button of the control R/C power on
TV
3.1. MAC Address and ESN and Wide-vine
Key Download
* The CI+ Key download is need for only PD22A/B/C Models.
* Connect TV SET and PC which download keys Writing
program by RS232C-Cable
(1) Start Program and Click ‘start’ Button to connect TV and
PC.
(2) When download succeed, you can see “OK” on the
screen.
* Each Chassis has it’s own MAC Address/ESN/Wide-vine
key. Please be careful of download.
3.2. DFT Process
* Depend on situation, Step can be changed.
* Condition spec
3.3. Tool OPTION (MANUAL)
(1) Press ADJ key on R/C to insert Tool OPTION
(2) On the “ Tool Option ”, Insert Tool Option by a number key
(3) Press the ENTER(■)
(4) Press ENTER(■) again.
(5) Select “OK to Download” by using ◄/►(VOL +/-) and
press ►(VOL +)
* PD22C
Model Name
PM970T
PM690T
PM680T PM670T PM470T
Tool
option 1
42 HD
33062
50 HD
33064
50 FHD
32808
32904
32920
32936
60 FHD
32810
32906
32922
32938
Tool
option 2
42 HD
66
50 HD
66
50 FHD
65
65
65
65
60 FHD
65
65
65
65
Tool option 3
9165
973
973
845
845
Tool option 4
29294
29294
29294
29294
29294
Tool option 5
47703
47703
47703
4770
14933
Tool option 6
1561
1561
1561
1561
1561
Tool option 7
8239
9263
8239
8239
8239
In case of France, Tool Option 5 is 47959/47959/47959/47957/15189.
Mode
Volume
Power Off
RF
0
DC On
Click on the first or last page to see other 50PM670T-ZA (CHASSIS:PD22C) service manuals if exist.