50PG6300-ZA (CHASSIS:PD85A) - LG TV Service Manual (repair manual). Page 10

Read LG 50PG6300-ZA (CHASSIS:PD85A) Service Manual online

 
­10­
       
7.3 Peak & average Brightness & Contrast measure standard specification 
      7.3.1 White Peak brightness measure specification 
1)  In non-impressed condition, measure peak brightness displayable as much as possible PDP module. 
2)  Measuring instrument: CS-1000, CA-210, CA-100+ or a sort of Color Analyzer.   
(Please adjust CA-210, CA-100+ by CS-1000 before measuring.) 
3)  Pattern Generator : VG-828 or a sort of digital pattern generator. 
(displayable Full White & 1/100 White Window pattern) 
4) Measure 
condition 
a.  Test pattern : in center, 1/10(H) * 1/10(V) of Window Pattern. 
(white pattern in non-impressed condition) 
b.  SET condition: Contrast Level => 100%, Brightness Level => Suitable Level (About 35~45). 
c.  Environment condition : Dark room in the non outside light   
5) Measurement 
a.  Do heat-run PDP module at 30minutes in normal temperature (25℃) by using full white pattern 
of 15% signal level (38 gray level). 
b.  Impress test pattern signal in 1/10(H) * 1/10(V) White Window of 100% (255Gray Level). 
c.  Measure 3 times brightness of central white window, and mark peak brightness in max 
brightness degree. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
d.  Measure the same condition in video signal /RGB signal. 
 
7.3.2 Average Brightness measure specification 
1)  Impress 100%(255Gray Level) full white pattern at the same peak brightness measurement. 
2)  Measure average brightness in 9 points.   
 
 
 
⑦ 
④ 
① 
⑨ 
⑥ 
③ 
⑧ 
⑤ 
② 
Page of 73
Display