50PG20C-UA (CHASSIS:PU84A) - LG TV Service Manual (repair manual). Page 7

Read LG 50PG20C-UA (CHASSIS:PU84A) Service Manual online

- 7 -
4-3. Confirmation
(1) We confirm whether “0xBF(480i)/0xC8(1080i)” address of
EEPROM “0xA2” is “0xAA” or not. 
(2) If “0xBF(480i)/0xC8(1080i)” address of EEPROM “0xA2”
isn’t “0xAA”, we adjust once more
(3) We can confirm the ADC values from “0xB9 ~ 0xBE(480i) /
0xC2 ~ (1080i)” addresses in a page “0xA2”
[
Manual ADC Confirmation using Service Remocon. After enter
Service Mode by pushing “INSTART” key.
Caution: Each PCB assembly must be checked by check JIG set.
(Because power PCB Assembly damages to PDP
Module, especially be careful)
Caution: Set up “RF mode(noise)” before voltage adjustment.
5. POWER PCB Ass’y Voltage 
Adjustment
(Va, Vs voltage Adjustment)
5-1. Test Equipment:
D.M.M 1EA
5-2. Connection Diagram for Measuring
Refer to Fig.1, Fig 2
5-3. Adjustment Method 
(1) 50” Va Adjustment (refer fig.1)
1) After receiving 100% Full White Pattern, HEAT RUN.
2) Connect + terminal of D.M.M. to Va pin of P802,
connect-terminal to GND pin of P802.
3) After turning VR902,voltage of D.M.M adjustment as
same as Va voltage which on label of panel right/top
(deviation; ±0.5V)
(2) 50” Vs Adjustment (refer fig.1)
1) Connect + terminal of D.M.M. to Vs pin of P802, connect
-terminal to GND pin of P802.
2) After turning VR901, voltage of D.M.M adjustment as
same as Vs voltage which on label of panel right/top
(deviation ; ±0.5V)
(3) 42” Va Adjustment (refer fig.2)    
1) After receiving 100% Full White Pattern, HEAT RUN.
2) Connect + terminal of D.M.M. to Va pin of P811, connect
-terminal to GND pin of P811.
3) After turning VR901,voltage of D.M.M adjustment as
same as Va voltage which on label of panel right/top
(deviation; ±0.5V)
(4) 42” Vs Adjustment (refer fig.2)
1) Connect + terminal of D. M..M. to Vs pin of P811,
connect -terminal to GND pin of P811.
2) After turning VR951, voltage of D.M.M adjustment as
same as Vs voltage which on label of panel right/top
(deviation ; ±0.5V)
ADJUSTMENT INSTRUCTIONS
(Fig. 1) 50inch Power PCB Assy Voltage Adjustment
(Fig. 2) 42inch Power PCB Assy Voltage Adjustment
Page of 48