50PB65-ZA (CHASSIS:PD73A) - LG TV Service Manual (repair manual). Page 11

Read LG 50PB65-ZA (CHASSIS:PD73A) Service Manual online

- 11 -
13. Default Value in Adjustment mode
13-1. Auto Color Balance
13-2. Write Balance
14. EEPROM Data Write(Serial No D/L)
14-1. Signal TABLE
CMD
: A0h 
LENGTH : 85~94h (1~16 bytes)
ADH
: E
2
PROM Sub Address high (00~1F)
ADL
: E
2
PROM Sub Address low  (00~FF)
Data
: Write data
CS
: CMD + LENGTH + ADH + ADL + Data_1 + ... + Data_n
Delay
: 20ms
14-2. Command Set
* Description
FOS Default write : <7mode data> write
Vtotal, V_Frequency, Sync_Polarity, Htotal, Hstart, Vstart, 0, Phase
Data write : Model Name and Serial Number write in EEPROM,.
14-3. Method & Notice
(1) Serial number D/L is using of scan equipment.
(2) Setting of scan equipment operated by Manufacturing
Technology Group.
(3) Serial number D/L must be conformed when it is produced
in production line, because serial number D/L is mandatory
by D-book 4.0.
15. Set Information(Serial No& Model name)
15-1. Setting up like bottom figure
(After setting white balance, this is set)
(Setting: Press ADJ Key in the Adjust remocon)
(1) Select  “System Control 2” by using 
E
(CH+/-) key, and
press 
(ENTER) Using Adjust remocon, RS-232 Host &
Baud Rate & Download value change)
15-2. Push the menu button in DTV mode.
(1) Select the STATION-> Diagno stics -> To set.
CMD LENGTH ADH ADL DATA_1
DATA_n
...
CS
DELAY
Model
Name
42PC55-ZB
50PC55-ZB
50PB65-ZA
Tool
Option1
2048
2052
2244
1697
1953
1977
0
0
0
14
14
14
2
2
2
1
1
1
192
192
192
Tool
Option2
Area
Option
Option1 Option2 Option3 Option3
No
1
EEPROM WRITE A0h
84h+n
n-byted Write
(n=1~16)
Adjust mode
CMD(hex) LENGTH(hex)
Description
(Fig. 7) Default on OSD
<Component>
<RGB>
<AV>
(Fig. 8) Default on OSD
Page of 53
Display

Click on the first or last page to see other 50PB65-ZA (CHASSIS:PD73A) service manuals if exist.