50LN5600-UI (CHASSIS:LA33B) - LG TV Service Manual (repair manual). Page 21

Read LG 50LN5600-UI (CHASSIS:LA33B) Service Manual online

- 21 -
5.7. HDMI ARC Function Inspection  
5.7.1. Test equipment
- Optic Receiver Speaker          
- MSHG-600 (SW: 1220 ↑) 
- HDMI Cable (for 1.4 version)
5.7.2. Test method
(1)  Insert  the  HDMI  Cable  to  the  HDMI ARC  port  from  the 
master equipment (HDMI1)
(2) Check the sound from the TV Set
(3)  Check  the  Sound  from  the  Speaker  or  using AV  &  Optic 
TEST program (It’s connected to MSHG-600)
* Remark:  Inspect in Power Only Mode and check SW version 
in a master equipment
5.8. Ship-out mode check (In-stop)  
▪ After final inspection, press In-Stop key of the Adj. R/C and 
check that the unit goes to Stand-by mode        
6. AUDIO output check
6.1. Audio input condition
(1) RF input: Mono, 1KHz sine wave signal, 100% Modulation
(2) CVBS, Component: 1KHz sine wave signal (0.4Vrms)
(3) RGB PC: 1KHz sine wave signal (0.7Vrms)
6.2. Specification
No
Item
Min
Typ Max Unit
Remark
1
Audio 
practical 
max Output, 
L/R
(Distor-
tion=10% 
max Output)
9.0
8.5
10.0
8.9
12.0
9.9
W
Vrms
(1)  Measurement 
condition
   -  EQ/AVL/Clear 
Voice: Off
(2)  Speaker (8Ω 
Impedance)
7. GND and HI-POT Test
7.1. GND & HI-POT auto-check preparation
(1)  Check  the  POWER  CABLE  and  SIGNAL  CABE  insertion 
condition
7.2. GND & HI-POT auto-check
(1)  Pallet moves in the station. (POWER CORD / AV CORD is 
tightly inserted)
(2) Connect the AV JACK Tester.
(3) Controller (GWS103-4) on.
(4) GND Test (Auto) 
- If Test is failed, Buzzer operates.
- If Test is passed, execute next process (Hi-pot test).       
  (Remove A/V CORD from A/V JACK BOX) 
(5) HI-POT test (Auto)
 - If Test is failed, Buzzer operates.
 -  If Test is passed, GOOD Lamp on and move to next process 
automatically.
7.3. Checkpoint
(1) Test voltage
- GND: 1.5KV/min at 100mA
- SIGNAL: 3KV/min at 100mA
(2) TEST time: 1 second
(3) TEST POINT
- GND Test = POWER CORD GND and SIGNAL CABLE GND.
- Hi-pot Test = POWER CORD GND and LIVE & NEUTRAL.
(4) LEAKAGE CURRENT: At 0.5mArms
Page of 121
Display