50LA66XX, 50LA6608, 50LA660S (CHASSIS:LD33B) - LG TV Service Manual (repair manual). Page 19

Read LG 50LA66XX / 50LA6608 / 50LA660S (CHASSIS:LD33B) Service Manual online

- 19 -
4.7. LNB voltage and 22KHz tone check
(only for DVB-S/S2 model)
▪ Test method
(1) Set TV in Adj. mode using POWER ON.
(2) Connect cable between satellite ANT and test JIG.
(3)  Press Yellow key(ETC+SWAP) in Adj Remote control to 
make LNB on.
(4) Check LED light ‘ON’ at 18 V menu.
(5) Check LED light ‘ON’ at 22 KHz tone menu.
(6)  Press Blue key(ETC+PIP INPUT) in Adj Remote control 
to make LNB off.
(7) Check LED light ‘OFF’ at 18 V menu.
(8) Check LED light ‘OFF’ at 22 KHz tone menu.
▪ Test result
(1)  After  press  LNB  On  key,  ‘18  V  LED’  and  ‘22  KHz  tone 
LED’ should be ON. 
(2)  After press LNB OFF key, ‘18 V LED’ and ‘22 KHz tone 
LED’ should be OFF. 
4.8. Option selection per country
4.8.1. Overview
- Option selection is only done for models in Non-EU 
4.8.2. Method
(1)  Press ADJ key on the Adj. R/C, then select Country Group 
Meun
(2)  Depending on destination, select Country Group Code 04 
or  Country  Group  EU  then  on  the  lower  Country  option, 
select  US,  CA,  MX.  Selection  is  done  using  +,  -  or  ►◄ 
key.
5. Tool Option selection
▪  Method : Press "ADJ" key on the Adjustment remote control, 
then select Tool option.
6. Ship-out mode check(In-stop)
▪  After final inspection, press "IN-STOP" key of the Adjustment 
remote  control  and  check  that  the  unit  goes  to  Stand-by 
mode.
7.1. Method
-  Check that Power cord is fully inserted to the SET.
  (If loose, re-insert)
-  Unit  fully  inserted  Power  cord, Antenna  cable  and A/V 
arrive to the auto-check process. 
- Connect D-terminal to AV JACK TESTER
- Auto CONTROLLER(GWS103-4) ON
- Perform GND TEST
- If NG, Buzzer will sound to inform the operator.
- If OK, changeover to I/P check automatically.
(Remove CORD, A/V form AV JACK BOX.)
- Perform I/P test
- If NG, Buzzer will sound to inform the operator.
-  If OK, Good lamp will lit up and the stopper will allow the 
pallet to move on to next process.
7.2. Checkpoint
▪ TEST voltage
- GND: 1.5 KV / min at 100 mA
- SIGNAL: 3 KV / min at 100 mA
▪ TEST time: 1 second
▪ TEST POINT
-  GND  TEST  =  POWER  CORD  GND  &  SIGNAL  CABLE 
METAL GND
NEUTRAL
▪ LEAKAGE CURRENT: At 0.5 mArms
8. Audio
Measurement condition:
(1) RF input: Mono, 1 KHz sine wave signal, 100 % Modulation
(2) CVBS, Component: 1 KHz sine wave signal 0.5 Vrms
(3) RGB PC: 1 KHz sine wave signal 0.7 Vrms
No.
Item
Min
Typ
Max
Unit
Remark
1.
Audio practical 
max Output, L/R
(Distortion=10% 
max Output)
9
10
12
W
EQ Off
AVL Off
Clear Voice Off
8.10
10.8
Vrms
2.
Speaker (8Ω
Impedance)
9
10
12
W
Page of 127
Display

Click on the first or last page to see other 50LA66XX / 50LA6608 / 50LA660S (CHASSIS:LD33B) service manuals if exist.