Read LG 47LX9500-UA (CHASSIS:LA02R) Service Manual online
- 17 -
5.8. Ship-out mode check (In-stop)
• After final inspection, press In-Stop key of the Adj. R/C and
check that the unit goes to Stand-by mode.
• After final inspection, Always turn on the Mechanical S/W.
6. GND and Hi-pot Test
6.1. Method
6.1.1. GND & HI-POT auto-check preparation
(1) Check the POWER CABLE and SIGNAL CABE
insertion condition (If loose, re-insert)
- Unit fully inserted POWER cord, Antenna cable and A/V
arrive to the auto-check process.
- Connect D-terinal to AV JACK TESTER
- Auto CONTROLLER(GWS103-4) ON
- Perform GND Test
- If NG, Buzzer will sound to inform the operator.
- If OK, change over to I/P check auto matically.
(Remove CORD, A/V form AV Jack Box)
- Perform I/P test
- If NG, Buzzer will sound to inform the operator.
- If OK, Good lamp will lit up and the stopper will allow the
arrive to the auto-check process.
- Connect D-terinal to AV JACK TESTER
- Auto CONTROLLER(GWS103-4) ON
- Perform GND Test
- If NG, Buzzer will sound to inform the operator.
- If OK, change over to I/P check auto matically.
(Remove CORD, A/V form AV Jack Box)
- Perform I/P test
- If NG, Buzzer will sound to inform the operator.
- If OK, Good lamp will lit up and the stopper will allow the
pallet to move on to next process.
6.2. Checkpoint
• TEST voltage
- GND: 1.5KV/min at 100mA
- SIGNAL: 3KV/min at 100mA
- SIGNAL: 3KV/min at 100mA
• TEST time: 1 second
• TEST POINT
• TEST POINT
- GND TEST = POWER CORD GND & SIGNAL CABLE
METAL GND
NEUTRAL
• LEAKAGE CURRENT: At 0.5mArms
7. EYE-Q function check
1) Turn on TV
2) Press EYE button on the adjustable R/C
3) Hide the Eye Q sensor on the front of the set for
approximately 6 seconds.
4) Check the “Sensor Data” whether it is under 10. If it is not
4) Check the “Sensor Data” whether it is under 10. If it is not
under 10, Eye Q sensor is faulty. And change a new
sensor.
sensor.
5) Detach the hand from Eye Q II sensor for 6 seoconds.
6) Check the value of “Back Light(xxx)” on the display. If its
6) Check the value of “Back Light(xxx)” on the display. If its
value does not increase after 6 senconds, Eye Q sensor is
faulty.
faulty.
8. Check the R/C
- Required Equipments: RF-controller, IR-KEY-CODE
controller
- Check that AA Battery of RF-Remote controller is enough
before the test.
(Recommend that change the battery each LOT)
- Test Method
a) Press the START button on Controller for pairing with the
set
b) Check whether cursor is showed on a display of the set
after pressing the OK button.
c) Press the STOP button to pair off with the set.
<Step2>
<Step3>
<Step4>
<Step5>
<Step6>
Click on the first or last page to see other 47LX9500-UA (CHASSIS:LA02R) service manuals if exist.