Read LG 42PX7DC-UA (CHASSIS:AF-05PA) Service Manual online
- 12 -
7. POWER PCB Assy Voltage
Adjustment
(Va, Vs Voltage Adjustment)
7-1. Test Equipment :
D.M.M 1EA
7-2. Connection Diagram for Measuring
Refer to Fig 1.
7-3. Adjustment
(1) Va Adjustment
1) Connect + terminal of D.M.M to Va pin of P805 and
connect – terminal to GND pin of P805.
2) Adjust RV601 voltage to match that of the label on the
Top/Right of the panel. (Deviation : ±0.5V)
(2) Vs Adjustment
1) Connect + terminal of D.M.M to Vs pin of P805 and
connect – terminal to GND pin of P805.
2) Adjust RV401 voltage to match that of the label on the
Top/Right of the panel. (Deviation : ±0.5V)
8. EDID(The Extended Display
Identification Data)/DDC
(Display Data Channel) Download
(Display Data Channel) Download
This is the function that enables “Plug and Play".
8-1. HDMI EDID Data Input
(1) Required Test Equipment
1) PC, Jig for adjusting DDC. (PC serial to D-sub
Connection equipment)
2) S/W for writing DDC(EDID data write & read)
3) D-Sub cable
4) Jig for HDMI Cable connection
3) D-Sub cable
4) Jig for HDMI Cable connection
(2) Preparation for Adjustments &
Setting of Device
1) Set devices as below and turn on the PC and JIG.
2) Open S/W for writing DDC (EDID data write & read).
2) Open S/W for writing DDC (EDID data write & read).
(operated in DOS mode)
8-2. EDID DATA for AF-05PA
[Caution] Enter the POWER ON MODE by pressing POWER
ON key on the SVC Remote control and download.
:
EDID for HDMI (DDC (Display Data Channel) Data)
EDID table =
HDMI1(FDED)
EDID table =
HDMI1(FDED)
0 1 2 3 4 5 6 7 8 9 A B C D E F
___________________________________________________
0 | 00 FF FF FF FF FF FF 00 1E 6D 01 00 01 01 01 01
10 | 00 0F 01 03 80 73 41 96 0A CF 74 A3 57 4C B0 23
20 | 09 48 4C 2F CE 00 31 40 45 40 61 40 01 01 01 01
30 | 01 01 01 01 01 01 64 19 00 40 41 00 26 30 18 88
40 | 36 00 00 D0 52 00 00 18 00 00 00 FD 00 38 55 1F
50 | 3C 08 00 0A 20 20 20 20 20 20 00 00 00 FC 00 34
60 | 32 50 58 37 44 43 2D 55 41 0A 20 20 00 00 00 FC
70 | 00 50 44 50 0A 20 20 20 20 20 20 20 20 20 01 FD
ADJUSTMENT INSTRUCTIONS
Each PCB Assy must be checked by Check JIG Set before
assembly. (Especially, be careful Power PCB Assy which can
cause Damage to the PDP Module.)
assembly. (Especially, be careful Power PCB Assy which can
cause Damage to the PDP Module.)
<Fig. 1> Connection Diagram of Power Adjustment for
Measuring (Power Board): 42”
PDP TV SET
(or Digital Board)
<Fig. 2>
Click on the first or last page to see other 42PX7DC-UA (CHASSIS:AF-05PA) service manuals if exist.