42PW340-UB, 42PW350-UA, 42PW350-UE, 42PW350U-UC (CHASSIS:PU11A) - LG TV Service Manual (repair manual). Page 11

Read LG 42PW340-UB / 42PW350-UA / 42PW350-UE / 42PW350U-UC (CHASSIS:PU11A) Service Manual online

* Attachment: White Balance adjustment coordination and color
temperature.
O
Using CS-1000 Equipment. 
- COOL : T=11000K, _uv=0.000, x=0.276 y=0.283 
- MEDIUM  : T=9300K, _uv=0.000, x=0.285 y=0.293 
- WARM  : T=6500K, _uv=0.000, x=0.313 y=0.329 
O
Using CA-210 Equipment. (10 CH)
- Contras value : 216 Gray
- Brighness spec.
6. Test of RS-232C control.
- Press In-Start button of Service Remocon then set the “4.Baud
Rate” to 115200. Then check RS-232C control and 
7. Selection of Country option.
model (Not allowed Korean model). It is selection of Country
about Rating and Time Zone.
(1) Models: All models which PB82C Chassis (See the first
page.) 
(2) Press “In-Start” button of Service Remocon, then enter the
“Option” Menu with “PIP CH-“ Button 
(3) Select one of these three (USA, CANADA, MEXICO)
defends on its market using “Vol. +/-“button.
Caution : Don’t push The INSTOP KEY after completing the
function inspection
Caution : Inspection only PAL M / NTSC
8. GND and ESD Testing
8-1. Prepare GND and ESD Testing.
- Check the connection between set and power cord
8-2. Operate GND and ESD auto-test.
(1) Fully connected (Between set and power cord) set enter
the Auto-test sequence.
(2) Connect D-Jack AV jack test equipment.
(3) Turn on Auto-controller(GWS103-4)
(4) Start Auto GND test.
(5) If its result is NG, then notice with buzzer.
(6) If its result is OK, then automatically it turns to ESD Test.
(7) Operate ESD test
(8) If its result is NG, then notice with buzzer.
(9) If its result is OK, then process next steps. Notice it with
Good lamp and STOPER Down.
8-3. Check Items.
(1) Test Voltage 
GND: 1.5KV/min at 100mA
Signal: 3KV/min at 100mA
(2) Test time: just 1 second.
(3) Test point
- GND test: Test between Power cord GND and Signal
cable metal GND.
- ESD test: Test between Power cord GND and Live and
neutral.
(4) Leakage current: Set to 0.5mA(rms)
9. POWER PCB Ass’y Voltage
Adjustment
(Va/Vs Voltage Adjustment)
(1)Test equipment : D.M.M 1EA
(2) Connection Diagram for Measuring : refer to fig.1 
- 11 -
Color Test 
Color 
Coordination
temperature
Equipment
x
y
COOL
CA-210
0.276
±0.002
0.283
±0.002
MEDIUM
CA-210
0.285
±0.002
0.293
±0.002
WARM
CA-210
0.313
±0.002
0.329
±0.002
Item
Min
Typ Max Unit Remark
White  
49
60
-
cd/m - 100%Window White 
average
Pattern
brightness
- 100IRE(255Gray)
- Picture: Vivid(Medium )
Brightness 
-20
+20
%
- 85IRE(216Gray) 100% 
uniformity
Window White Pattern
- Picture: Vivid(Medium)
< fig.1 : 42 inch Power PCB Assy Voltage adjustment >
Page of 72