42PG6HD-UA (CHASSIS:PU83A) - LG TV Service Manual (repair manual). Page 4

Read LG 42PG6HD-UA (CHASSIS:PU83A) Service Manual online

- 4 -
INSTRUCCIONES DE AJUSTE
1. Application Range
This spec sheet is applied all of the PDP TV, PU83A chassis. 
2. Specification
(1) Because this is not a hot chassis, it is not necessary to use
an isolation transformer. However, the use of isolation
transformer will help protect test equipment.
(2) Adjustments must be done in the correct order.
(3) The adjustments must be performed in the circumstance of
25±5°C of temperature and 65±10% of relative humidity if
there is no specific designation.
(4) The input voltage of the receiver be must kept 220V, 60Hz
when adjusting.
(5) The receiver must be operational for about 15 minutes
prior to the adjustments.
1) After receiving 100% white pattern, the receiver must be
operated prior to adjustment. (Or 8. Test Pattern
condition in EZ - Adjust)
2) Enter into White Pattern 
- Press POWER ON Key on the Service Remote
Control (S R/C)
- Enter the Ez - Adjust by pressing ADJ Key on the
Service Remote Control (S R/C).
- Select 10. Test Pattern using the CH +/- Key and
select the White by pressing the direction Key. 
Display the 100% Full White Pattern. 
[
Set is activated HEAT-RUN without signal generator in
this mode.
O
HEAT RUN
Preliminary action is applied to the test for afterimage
discharge detection, and 100% FULL WHITE PATTERN
must be operated automatically.
O
Test for afterimage discharge detection
1) Pressing Power On key
- Only operating by pressing Power On key
2) Full Test Pattern(2 min 30sec) --> Full Black
Pattern(30sec) --> Full White Pattern(maintenance)
- Full White Pattern when the main power is turned on
again after being turned off 
3) Pattern Mode is deselected by pressing CH +/-, Exit Key.
[
Set is activated HEAT-RUN without signal generator in this
mode.
If you turn on a still screen more than 20 minutes (Especially
Digital pattern(13 CH), Cross Hatch Pattern), an afterimage
may occur in the black level part of the screen.
Test Pattern 2min 30sec
Test Pattern 30sec
Page of 27
Display

Click on the first or last page to see other 42PG6HD-UA (CHASSIS:PU83A) service manuals if exist.