42PC52-ZD (CHASSIS:PP78A) - LG TV Service Manual (repair manual). Page 12

Read LG 42PC52-ZD (CHASSIS:PP78A) Service Manual online

- 12 -
8. Tool Option Area Option Change
8-1. Profile 
: Must be changed the option value because being different with
some setting value depend on module, inch and market.
8-2. Required Test Equipment
1) Adjustment remocon.
8-3. Adjustment method
Before PCB check, have to change the Tool option and Area option.
Option values are below.
(If on changed the option, the input menu can differ the model spec.)
The input methods are same as other chassises.(Use adj Key
on the Adjust Remocon)
9. Color carrier Adjustment
(Inspection process)
9-1. Profile 
:  To  have  the  margin  about  the  deviation  of  colorcarrier  to
satisfy the spec.
9-2. Required Test Equipment
1) Adjustment remocon.
2) Pal RF signal.
9-3. Connection
: TV set should connected with the pal RF signal(EU 5CH).
9-4. Adjustment method
(1) tuning the RF signal
ZB, TB : PAL Philips Pattern (with Color Bar)
(2) push the “adj” key in the adjustment remocon.
10. POWER PCB Assy Voltage
Adjustments 
(Va, Vs Voltage adjustments)
10-1. Profile 
: To supply the Va, Vs voltage that the module want.
10-2. Required Test Equipment
(1) Stick for adjustment.
(2) DMM.
10-3. Connection structure
10-4. Connection Diagram for Measuring
: refer to (Fig. 1)
10-5. Adjustment Method
(1) Va Adjustment
1) After receiving 100% Full White Pattern, HEAT RUN.
2) Connect + terminal of D. M..M. to Va pin of P812, connect
-terminal to GND pin of P812.
3)  After  turning  VR901,voltage  of  D.M.M  adjustment  as
same  as  Va  voltage  which  on  label  of  panel  right/top.
(deviation; 
±0.5V)
(2) Vs Adjustment
1) Connect + terminal of D. M..M. to Vs pin of P812, connect
-terminal to GND pin of P812.
2)  After  turning  VR951,  voltage  of  D.M.M  adjustment  as
same  as  Vs  voltage  which  on  label  of  panel  right/top.
(deviation ; 
±0.5V)
11. EDID
(The Extended Display Identification Data )
/DDC
(Display Data Channel)
download
11-1. Profile 
: To be possible for plug and play.
11-2. EDID Data
* Caution
- Use the proper signal cable for EDID Download.
- Never connect HDMI & D-SUB Cable at the same time.
- Use the proper cables below for EDID Writing.
* EDID Data
Tool Option
Inch
ZB
TB
42(VGA)
02244
04292
42(XGA)
02252
04300
50
02260
04308
Area Option
Depend on PR
Item
Manufacturer ID
Version
Revision
Condition
GSM
Digital : 1
Digital : 3
Hex Data
1E6D
01
03
For RGB EDID
For HDMI EDID
(Fig. 1) Connection Diagram of power adjustment for measuring.
Each PCB assembly must be checked by check JIG set.
(Because  power  PCB  Assembly  damages  to  PDP  Module,
especially be careful)
Page of 40
Display

Click on the first or last page to see other 42PC52-ZD (CHASSIS:PP78A) service manuals if exist.