42PC1D-UB, 42PC1DA-UB (CHASSIS:PA-61B) - LG TV Service Manual (repair manual). Page 10

Read LG 42PC1D-UB / 42PC1DA-UB (CHASSIS:PA-61B) Service Manual online

- 10 -
(2) Select "Configure -> Select Device".
(3) When the "Select Device" window appears, select the
PIC18F1220 from "Device" and press OK.
(4) Select "Programmer -> Connect".
When connected with the Micom, the display message on
the Output window appears as below. 
(5) Select "File -> Import", select the Work HEX file and open.
(6) Select "Programmer -> Program".
(7) Download is executed and about 5 seconds later, the
"Programming succeeded" message is displayed on the
Output window and the Download process is ended. 
(8) The execution of process (6) is convenient when using the
short-cut icon. 
5. POD Certificate Download  
5-1. Preparation for Adjustment
(1) Connect the MEMORY JIG and PC.
(2) Turn on the JIG MAIN POWER SWITCH.
(3) After turn on the PC and MONITOR, execute the
‘Certificate Downloader v1.4’  from the screen.
5-2. Adjustment Sequence
(1) After open the ‘Certificate Downloader v1.4’, enter
Connection set and set the as same below.
The port settings are determined by each PC's setup.
ADJUSTMENT INSTRUCTIONS
Page of 46
Display

Click on the first or last page to see other 42PC1D-UB / 42PC1DA-UB (CHASSIS:PA-61B) service manuals if exist.