42PA4500-DF, 42PA4510-DC (CHASSIS:PB21A) - LG TV Service Manual (repair manual). Page 10

Read LG 42PA4500-DF / 42PA4510-DC (CHASSIS:PB21A) Service Manual online

- 10 -
●  When tester will measure on Cool condition, adjust W30 on 
TV display menu.
●  When tester will measure on medium condition, adjust 0 on 
TV display menu.
●  When tester will measure on warm condition, adjust W30 on 
TV display menu.
● Using CA-210 Equipment. (10 CH)
- Contrast value: 216 Gray
- Brightness spec.
5.3. Test of RS-232C control. 
-  Press In-Start button of Service Remocon then set the 
“4.Baud Rate” to 115200. Then check RS-232C control and 
5.4. Selection of Country option.
model (Not allowed Korean model). It is selection of Country 
about Rating and Time Zone.
■  Models: All models which PU11A Chassis (See the first 
page.) 
■  Press “In-Start” button of Service Remocon, then enter the 
“Option” Menu with “PIP CH-“ Button 
■  Select one of these three (USA, CANADA, MEXICO) de-
pends on its market using “Vol. +/-“button.
* Caution :  Don’t push The INSTOP KEY after completing the 
function inspection.
* Caution : Inspection only PAL M / NTSC 
6. GND and ESD Testing
6.1. Prepare GND and ESD Testing.
■ Check the connection between set and power cord
6.2. Operate GND and ESD auto-test.
■  Fully connected (Between set and power cord) set enter the 
Auto-test sequence.
■ Connect D-Jack AV jack test equipment.
■ Turn on Auto-controller(GWS103-4)
■ Start Auto GND test.
■ If its result is NG, then notice with buzzer.
■ If its result is OK, then automatically it turns to ESD Test.
■ Operate ESD test
■ If its result is NG, then notice with buzzer.
■  If its result is OK, then process next steps. Notice it with 
Good lamp and STOPER Down.
6.3. Check Items.
■ Test Voltage 
● GND: 1.5KV/min at 100mA
● Signal: 3KV/min at 100mA
■ Test time: just 1 second.
■ Test point
●  GND test: Test between Power cord GND and Signal 
cable metal GND.
●  ESD test: Test between Power cord GND and Live and 
neutral.
■ Leakage current: Set to 0.5mA(rms)
6.4. POWER PCB Ass’y Voltage adjustment 
          (Va, Vs voltage adjustment)
6.4.1. Test equipment 
D.M.M 1EA
6.4.2. Connection Diagram for Measuring 
          
: refer to fig.1  
<XPOWER4 42T4 PSU>
6.4.3. Adjustment method
 
6.4.3.1. Vs adjustment (refer fig.1)
(1)  Connect + terminal of D.M.M. to Vs pin of P811, connect 
-terminal to GND pin of P811
(2)  After turning VR901, voltage of D.M.M adjustment as same 
as Vs voltage which on label of panel left/top  ( deviation ; 
±0.5V)
6.4.3.2. Va adjustment (refer fig.1)
(1) After receiving 100% Full White Pattern, HEAT RUN.
(2)  Connect + terminal of D.M.M. to Va pin of P811, connect 
-terminal to GND pin of P811
(3)  After turning VR502,voltage of D.M.M adjustment as same 
as Va voltage which on label of panel left/top (deviation; 
±0.5V)
Color 
temperature
Test 
Equipment
Color Coordination
x
y
COOL
CA-210
0.276 ± 0.002 0.283 ± 0.002
MEDIUM
CA-210
0.285 ± 0.002 0.293 ± 0.002
WARM
CA-210
0.313 ± 0.002 0.329 ± 0.002
Item
White average
 brightness
Brightness uniformity
Min
49
-20
Typ
60
Max
+20
Unit
cd/m²
%
Remark -  100% Window White 
Pattern
- 100IRE(255Gray)
- Picture: Vivid(Medium)
-  85IRE(216Gray) 100% 
Window White Pattern
- Picture: Vivid(Medium)
(fig.1) PCB Assy Voltage adjustment
Page of 48
Display

Click on the first or last page to see other 42PA4500-DF / 42PA4510-DC (CHASSIS:PB21A) service manuals if exist.