42LV770S (CHASSIS:LD12D) - LG TV Service Manual (repair manual). Page 13

Read LG 42LV770S (CHASSIS:LD12D) Service Manual online

- 13 -
4.5. EYE-Q function check
Step 1) Turn on TV.
Step 2) Press EYE key of Adjustment remote control.
Step 3) Cover the Eye Q II sensor on the front of the using
your hand and wait for 6 seconds.
Step 4) Confirm that R/G/B value is lower than 10 of the “Raw
Data (Sensor data, Back light)”. If after 6 seconds,
R/G/B value is not lower than 10, replace Eye Q II
sensor.
Step 5) Remove your hand from the Eye Q II sensor and wait
for 6 seconds.
Step 6) Confirm that “ok” pop up. If change is not seen,
replace Eye Q II sensor.
4.6. Local Dimming Function Check
(1) Turn on TV.
(2) At  the  Local Dimming mode, module Edge Backlight
moving Top to Bottom Back light of IOP module moving.
(3) Confirm the Local Dimming mode.
(4) Press “exit” key
4.7. Magic Motion Remote control test
- Equipment : RF Remote control for test, IR-KEY-Code
Remote control for test
- You must confirm the battery power of RF-Remote control
before test.(recommend that change the battery per every lot) 
- Sequence (test)
1) if you select the ‘start key(Mute)’ on the controller, you can
pairing with the TV SET.
2) You can check the cursor on the TV Screen, when select
the ‘OK’ key on the controller.
3) You must remove the pairing with the TV Set by select
‘Vol+(STOP)’ key on the controller.
4.8. RF emitter inspection
(1) Start 3D pattern inspection
(2) If RF emitter signal is correctly received to RF receiver, the
lamp of RF tester turn on.
4.9. Option selection per country
(1) Overview
- Option selection is only done for models in Non-EU.
- Applied model: LD12D/N Chassis applied EU model.
(2) Method
1) Press ADJ key on the Adjustment remote control, then
select Country Group Menu.
2) Depending on destination, select Country Group Code
04 or Country Group EU then on the lower Country
option, select US, CA, MX. Selection is done using +, -
or 
GF
KEY.
4.10. Tool Option selection
- Method : Press Adj. key on the Adjustment remote control,
then select Tool option.
4.11. Ship-out mode check(In-stop)
After final inspection, press IN-STOP key of the Adjustment
remote control and check that the unit goes to Stand-by mode.
<IR Tester Lamp turned off(NG)>
<IR Emitter inspection>
<IR Tester Lamp turned on(OK)>
Page of 86
Display

Click on the first or last page to see other 42LV770S (CHASSIS:LD12D) service manuals if exist.