42LV5500-TA, 42LV550Y (CHASSIS:LB12E) - LG TV Service Manual (repair manual). Page 14

Read LG 42LV5500-TA / 42LV550Y (CHASSIS:LB12E) Service Manual online

- 14 -
4.8. Option selection per country
(1) Overview
- Option selection is only done for models in Non-AU/ -ID/ -
SG/ -MY/ -VN/ -IL/ -ZA/ -IR.
model.
(2) Method
1) Press ADJ key on the Adj. R/C, then select Country
Group Meun.
2) Depending on destination, select Country Group Code
12 or Country Group A-ASIA.
3) Press ADJ key on the Adj. R/C, then select Area Option. 
4) Depending on Area code number, select Default Lang.,
Wi-Fi Frequency, Lang Gr., Teletext Lang Gr., I II Save,
HDEV, MONO, Location.
4.9. Tool Option selection
- Method : Press Adj. key on the Adj. Remote Control, then
select Tool option.
4.10. Ship-out mode check(In-stop)
After final inspection, press IN-STOP key of the Adjustment
remote control and check that the unit goes to Stand-by mode.
(1) Method
- Check that Power Cord is fully inserted to the SET.
(If loose, re-insert)
- Unit fully inserted Power cord, Antenna cable and A/V
arrive to the auto-check process. 
- Connect D-terminal to AV JACK TESTER
- Auto CONTROLLER(GWS103-4) ON
- Perform GND TEST
- If NG, Buzzer will sound to inform the operator.
- If OK, changeover to I/P check automatically.
(Remove CORD, A/V form AV JACK BOX)
- Perform I/P test.
- If NG, Buzzer will sound to inform the operator.
- If OK, Good lamp will lit up and the stopper will allow
the pallet to move on to next process.
(2) Checkpoint
• TEST voltage
- GND: 1.5 KV / min at 100 mA
- SIGNAL: 3 KV / min at 100 mA
• TEST time: 1 second
• TEST POINT
- GND TEST = POWER CORD GND & SIGNAL CABLE
METAL GND
& NEUTRAL
• LEAKAGE CURRENT: At 0.5 mArms
5. Audio
Measurement condition:
1. RF input: Mono, 1 KHz sine wave signal, 100 % Modulation
2. CVBS, Component: 1 KHz sine wave signal 0.5 Vrms
3. RGB PC: 1 KHz sine wave signal 0.7 Vrms
6. USB S/W download(Service only)
1) Put the USB Stick to the USB socket.
2) Automatically detecting update file in USB Stick.
- If your downloaded program version in USB Stick is Low,
it didn’t work. But your downloaded version is High, USB
data is automatically detecting.
3) Show the message “Copying files from memory”
4) Updating is starting.
5) Updating Completed, the TV will restart automatically.
6) If your TV is turned on, check your updated version and
Tool option. (explain the Tool option, next stage)
* If downloading version is more high than your TV have, TV
can lost all channel data. In this case, you have to channel
recover. if all channel data is cleared, you didn’t have a
DTV/ATV test on production line.
* After downloading, have to adjust TOOL OPTION again.
1) Push “IN-START” key in service remote control.
2) Select “Tool Option 1” and push “OK” key.
3) Punch in the number. (Each model has their number.)
No.
Item
Min.
Typ.
Max.
Unit
1. 
Audio practical max
9.0
10.0
12.0
W
EQ Off
Output, L/R
AVL Off
(Distortion=10 %
8.5
8.9
9.8
Vrms
Clear Voice Off
max Output)
2. 
Speaker (8 Ω
10.0
15.0
W
EQ On
Impedance)
AVL On
Clear Voice On
Module
Tool 1
Tool 2
Tool 3
Tool 4
Tool 5
Tool 6
Remark
LGD
32998
715
3327
17592
8789
662
STD B/L: 55
AUO
37094
715
3327
17592
8917
665
Page of 116
Display

Click on the first or last page to see other 42LV5500-TA / 42LV550Y (CHASSIS:LB12E) service manuals if exist.