Read LG 42LS3450 (CHASSIS:LA25C) Service Manual online
- 6 -
ADJUSTMENT INSTRUCTION
1. Application Range
This spec. sheet applies to LA25C Chassis applied LCD TV all
models manufactured in TV factory.
2. Specification
(1) Because this is not a hot chassis, it is not necessary to use
an isolation transformer. However, the use of isolation
transformer will help protect test instrument.
(2) Adjustment must be done in the correct order.
(3) The adjustment must be performed in the circumstance of
25 ±5 °C of temperature and 65±10% of relative humidity if
there is no specific designation.
(4) The input voltage of the receiver must keep 100~240V,
50/60Hz.
(5) At first Worker must turn on the SET by using Power Only
key.
(6) The receiver must be operated for about 5 minutes prior to
the adjustment when module is in the circumstance of over
15 °C
In case of keeping module is in the circumstance of 0°C, it
should be placed in the circumstance of above 15°C for 2
hours
In case of keeping module is in the circumstance of below
-20°C, it should be placed in the circumstance of above
15°C for 3 hours
[Caution]
When still image is displayed for a period of 20 minutes or
longer (especially where W/B scale is strong.
Digital pattern 13ch and/or Cross hatch pattern 09ch), there
can some afterimage in the black level area
3. Adjustment items
3.1. Main PCBA Adjustments
(1) ADC adjustment: Component 480i, 1080p / RGB-PC 1080p
(2) EDID downloads for HDMI and RGB-PC
3.2. Final assembly adjustment
(1) White Balance adjustment
(2) RS-232C functionality check
(3) Factory Option setting per destination
(4) Shipment mode setting (IN-STOP)
(5) GND and HI-POT test
3.3. Appendix
(1) Shipment conditions
(2) Tool option menu
(3) USB Download (S/W Update, Option and Service only)
(4) Preset CH Information
4. MAIN PCBA Adjustments
* Download
(1) Execute ISP program “Mstar ISP Utility” and then click
“Config” tab.
(2) Set as below, and then click “Auto Detect” and check “OK”
message. If display “Error”, Check connect computer, jig, and
set.
(3) Click “Connect” tab. If display “Can’t ”, Check connect
computer, jig, and set.
(4) Click “Read” tab, and then load download file(XXXX.bin) by
clicking “Read”
(5) Click “Auto” tab and set as below
(6) Click “Run”.
(7) After downloading, check “OK” message.
Click on the first or last page to see other 42LS3450 (CHASSIS:LA25C) service manuals if exist.