42LP360H (CHASSIS:LA3AA) - LG TV Service Manual (repair manual). Page 15

Read LG 42LP360H (CHASSIS:LA3AA) Service Manual online

- 15 -
4.5. Outgoing condition Configuration
■  When  pressing  IN-STOP  key  by  SVC  remocon,  Red  LED 
are blinked alternatively. And then automatically turn off.
   (Must not AC power OFF during blinking)
4.6. GND & Hi-pot test
4.6.1. GND & HI-POT auto-check preparation 
(1)  Check  the  POWER  CABLE  and  SIGNAL  CABE  insertion 
condition
4.6.2. GND & HI-POT auto-check 
(1)  Pallet moves in the station. (POWER CORD / AV CORD is 
tightly inserted)
(2) Connect the AV JACK Tester.
(3) Controller (GWS103-4) on.
(4) GND Test (Auto) 
     - If Test is failed, Buzzer operates.
     -  If  Test  is  passed,  execute  next  process  (Hi-pot  test). 
(Remove A/V CORD from A/V JACK BOX)
(5) HI-POT test (Auto)
     - If Test is failed, Buzzer operates.
     -  If  Test  is  passed,  GOOD  Lamp  on  and  move  to  next 
process automatically.
4.6.3. Checkpoint 
(1) Test voltage
 3 Poles 
    - GND: 1.5KV/min at 100mA
    - SIGNAL: 3KV/min at 100mA
 2 Poles
    - SIGNAL: 3KV/min at 100mA
(2) TEST time: 1 second
(3) TEST POINT
 3 Poles
    -  GND Test  =  POWER  CORD  GND  and  SIGNAL  CABLE 
GND.
    -  Hi-pot Test = POWER CORD GND and LIVE & NEUTRAL.
 2 Poles
   - Hi-pot Test = Accessible Metal and LIVE & NEUTRAL.
(4) LEAKAGE CURRENT: At 0.5mArms
Page of 36