42LN52XX, 42LN5200, 42LN5204 (CHASSIS:LD36M) - LG TV Service Manual (repair manual). Page 13

Read LG 42LN52XX / 42LN5200 / 42LN5204 (CHASSIS:LD36M) Service Manual online

- 13 -
* Auto-control interface and directions
(1)  Adjust in the place where the influx of light like floodlight 
around is blocked. (illumination is less than 10 lux).
(2)  Adhere closely the Color analyzer(CA210) to the module 
less than 10 cm distance, keep it with the surface of the 
Module and Color analyzer's prove vertically.(80° ~ 100°).
(3) Aging time
-  After aging start, keep the power on (no suspension of 
power supply) and heat-run over 5 minutes.
-  Using 'no signal' or 'POWER ONLY' or the others, check 
the back light on.
▪ Auto adjustment Map(using RS-232C to USB cable)
RS-232C COMMAND
[CMD  ID  DATA]
  Wb 
00  00 
White Balance Start
  Wb 
00  ff 
White Balance End
<Caution>
Color Temperature : COOL, Medium, Warm. 
One of R Gain/G Gain/ B Gain should be kept on 0xC0, and 
adjust  other  two  lower  than  C0.(When  R/G/B  Gain  are  all 
C0, it is the FULL Dynamic Range of Module)
* Manual W/B process using adjust Remote control.
▪ After enter Service Mode by pushing "ADJ" key,
▪  Enter  White  Balance  by  pushing  "►"  key  at  "9.  White 
Balance".
* CASE Cool Mode
First  adjust  the  coordinate  far  away  from  the  target 
value(x, y).B.
1) x, y > target
2) x, y < target
3) x >target, y < target
4) x < target, y > target
   -  Every 4 case have to fit y value by adjusting B Gain 
and then fit x value by adjusting R-Gain.
   -  In  this  case,  increasing/decreasing  of  B  Gain  and  R 
Gain can be adjusted.
How to adjust
1) In case G gain more than 172
    Adjust R Gain and B Gain less than 192 
2) if the G gain value be adjusted down to 172
     One of the R/B Gain is 254
3)  if G Gain is 172, More than one of R/B Gain is to be 
between 192~254.
* CASE Medium / Warm
First  adjust  the  coordinate  far  away  from  the  target 
value(x, y).
1) x, y > target
i) Decrease the R, G. 
2) x, y < target
i) First decrease the B gain, 
ii) Decrease the one of the others.
3) x > target, y < target
i) First decrease B, so make y a little more than the target.
ii) Adjust x value by decreasing the R
4) x < target, y > target
i) First decrease B, so make x a little more than the target.
ii) Adjust x value by decreasing the G
*  After you finished all adjustments, Press "In-start" key and 
compare Tool option and Area option value with its BOM, if 
it  is  correctly  same  then  unplug  the AC  cable.  If  it  is  not 
same, then correct it same with BOM and unplug AC cable.
For correct it to the model's module from factory Jig model.
*  Push  the  "IN  STOP"  key  after  completing  the  function 
inspection. And  Mechanical  Power  Switch  must  be  set 
“ON”.
4.3. Outgoing condition Configuration
■  When  pressing  IN-STOP  key  by  SVC  remocon,  Red  LED 
are blinked alternatively. And then automatically turn off.
(Must not AC power OFF during blinking)
RS-232C COMMAND
[CMD ID DATA]
MIN
CENTER
(DEFAULT)
MAX
Cool
Mid
Warm
Cool Mid Warm
R Gain jg
Ja
jd
00
172
192 192
254
G Gain jh
Jb
je
00
172
192 192
192
B Gain ji
Jc
jf
00
192
192 172
254
R Cut
64
64
64
128
G Cut
64
64
64
128
B Cut
64
64
64
128
EZ ADJUST
0. Tool Option1
1. Tool Option2
2. Tool Option3
3. Tool Option4
4. Tool Option5
5. Tool Option Commercial
6. Country Group
7. Area Option
8. ADC Calibration
9. White Balance
10. 10 Point WB
11. Test Pattern
12 EDID D/L
13. Sub B/C
14. Ext. Input Adjust
Whit Balance
Color Temp. 
 
R-Gain
G-Gain
B-Gain
R-Cut
G-Cut
B-Cut
Test-Pattern
Backlight
Reset 
      To Set
Cool
172
172
192
64
64
64
ON
100
Page of 75
Display

Click on the first or last page to see other 42LN52XX / 42LN5200 / 42LN5204 (CHASSIS:LD36M) service manuals if exist.