42LN5200 (CHASSIS:LT36M) - LG TV Service Manual (repair manual). Page 14

Read LG 42LN5200 (CHASSIS:LT36M) Service Manual online

- 14 -
4.5. V-COM Adjust (Only CDMS Module)
■  Why need Vcom adjustment?
     The  Vcom  (Common  Voltage)  is  a  Reference  Voltage  of 
Liquid Crystal Driving.
  → Liquid Crystal need for Polarity Change with every frame.
- Adjust sequence
■  Press  “P-only”  key,  enter  to  power  only  mode. And  Press 
“yellow”  key  to  enter  module  inspection  mode. After  then, 
Press “number 0” key, Flicker Pattern is displayed. 
    (Or After  enter  Service  Mode  by  pushing  “ADJ”  key,  then 
Enter  V-Com Adjust  mode  by  pushing  “►”  key  at  “13. 
V-Com”)
■  As  pushing  the  right  or  the  left  button  on  the  remote 
controller,  And  find  the  V-COM  value  Which  is  no  or 
minimized the Flicker.
    (If there is no flicker at default value, Press “P-only” key and 
finish the VCOM adjustment.)
■  Push the OK key to store value. Then the message “Saving 
OK” is pop.
■ Press the “P-only” key to finish VCOM adjustment.
4.6. Outgoing condition Configuration
■  When  pressing  IN-STOP  key  by  SVC  remocon,  Red  LED 
are blinked alternatively. And then automatically turn off.
   (Must not AC power OFF during blinking)
4.7. GND & Hi-pot test
4.7.1. GND & HI-POT auto-check preparation 
(1)  Check  the  POWER  CABLE  and  SIGNAL  CABE  insertion 
condition
4.7.2. GND & HI-POT auto-check 
(1)  Pallet moves in the station. (POWER CORD / AV CORD is 
tightly inserted)
(2) Connect the AV JACK Tester.
(3) Controller (GWS103-4) on.
(4) GND Test (Auto) 
     - If Test is failed, Buzzer operates.
     -  If  Test  is  passed,  execute  next  process  (Hi-pot  test). 
(Remove A/V CORD from A/V JACK BOX)
(5) HI-POT test (Auto)
     - If Test is failed, Buzzer operates.
     -  If  Test  is  passed,  GOOD  Lamp  on  and  move  to  next 
process automatically.
4.7.3. Checkpoint 
(1) Test voltage
 3 Poles 
    - GND: 1.5KV/min at 100mA
    - SIGNAL: 3KV/min at 100mA
 2 Poles
    - SIGNAL: 3KV/min at 100mA
(2) TEST time: 1 second
(3) TEST POINT
 3 Poles
    -  GND Test  =  POWER  CORD  GND  and  SIGNAL  CABLE 
GND.
    -  Hi-pot Test = POWER CORD GND and LIVE & NEUTRAL.
 2 Poles
   - Hi-pot Test = Accessible Metal and LIVE & NEUTRAL.
(4) LEAKAGE CURRENT: At 0.5mArms
5. Local Dimming Function Check
Step1) Turn on TV.
Step2)  Press  “P-only”  key,  enter  to  power  only  mode  and 
escape the “P-only” Mode by pressing “Exit” key
Step3) Press “Tilt” key, entrance to Local Dimming mode.
Step4)  At  the  Local  Dimming  mode,  module  Edge  Backlight 
moving Top to bottom Back light of module moving 
Step5) confirm the Local Dimming mode
Step6) Press “Exit” key
 
Row Line
Column Line
C
LC
C
ST
Panel
S
Y
S
T
E
M
Gate Dri
ve
 I
C
Source Drive IC
Circuit Block
Timing 
Controller
Power 
Block
V
COM
Gamma
Reference Voltage
Gamma Reference
Voltage
Data(R,G,B) & Control signal
Control signal
Data(R,G,B) &
Control signal
Interfac
e
TFT
Power Input
Power Input
Data Input
Data Input
V
COM
Liquid 
Crystal
V
COM
Page of 73
Display