Read LG 42LH40 (CHASSIS:LA92G) Service Manual online
- 7 -
5. Chroma& Luminance
No.
Item Specification
Min.
Typ.
Max.
Unit
Remark
1.
Max Luminance
Module
400
500
cd/m
2
(Center1-point/ Full white pattern)
2.
Luminance uniformity
Luminance
77
%
3. Contrast Ratio
1000: 1
1400: 1
4000: 1(DCR) 50000:1(DCR)
4.
Color Coordinates
RED
X
Typ
638
Typ
Y
-0.03
334
+0.03
GREEN
X
290
Y
606
BLUE
X
144
Y
064
WHITE
X 0.279
Y
0.292
5. Color Temperature
Cool
0.274
0.276
0.278
85% Full white pattern
0.281
0.283
0.285
**The W/B Tolerance is
Medium
0.283
0.285
0.287
± 0.015 for Adjustment
0.291
0.293
0.295
Dynamic contrast :off
Warm
0.311
0.313
0.315
Dynamic color :off
0.327
0.329
0.331
Energy saving mode :off
6.
Color Distortion, DG
10.0
%
7.
Color Distortion,DP
10.0
deg
8.
Color S/N,AM/FM
43.0
dB
9.
Color Killer Sensitivity
-80
dB
* Max Luminance &Contrast measure standard specification
- Max Luminance measure specification
1) In non-impressed condition, measure peak brightness displayable as much as possible LCD module.
2) Measuring instrument: CA-210 or a sort of Color Analyzer.
3) Pattern Generator :VG- 828 or a sort of digital pattern generator (displayable Full White &1/25 White Window pattern)
4) Measure condition
• Test pattern: in center,1/5(H)*1/5(V) of Window Pattern (white pattern in non-impressed condition)
• SET condition: Contrast &Brightness Level 100%
• Environment condition : Dark room in the non outside light
• Video menu option condition
1) In non-impressed condition, measure peak brightness displayable as much as possible LCD module.
2) Measuring instrument: CA-210 or a sort of Color Analyzer.
3) Pattern Generator :VG- 828 or a sort of digital pattern generator (displayable Full White &1/25 White Window pattern)
4) Measure condition
• Test pattern: in center,1/5(H)*1/5(V) of Window Pattern (white pattern in non-impressed condition)
• SET condition: Contrast &Brightness Level 100%
• Environment condition : Dark room in the non outside light
• Video menu option condition
5) Measurement
• Do heat-run LCD module at 30minutes in normal temperature (25°C)by using full white pattern of 15%signal level(38 gray level).
• Impress test pattern signal in 1/5(H)*1/5(V)White Window of 100%(255Gray Level)
• measure 3 times brightness of central white window,and mark peak brightness in max brightness degree
• measure the same condition in video signal /RGB signal.
• Do heat-run LCD module at 30minutes in normal temperature (25°C)by using full white pattern of 15%signal level(38 gray level).
• Impress test pattern signal in 1/5(H)*1/5(V)White Window of 100%(255Gray Level)
• measure 3 times brightness of central white window,and mark peak brightness in max brightness degree
• measure the same condition in video signal /RGB signal.
- Luminance uniformity measure specification
1) Impress 100%(255Gray Level) full white pattern at the same peak brightness measurement.
2) Measure average brightness in 5 points.
1) Impress 100%(255Gray Level) full white pattern at the same peak brightness measurement.
2) Measure average brightness in 5 points.
Signal
Picture Mode
Dynamic Contrast
Dynamic Color
Black Level
RF
NTSC-M
Vivid
High High Low
AV NTSC-J Vivid
High
High High
Component 720P
Vivid
High
High
High
RGB 1024x768
Vivid
NA
NA
NA
HDMI DTV
720P
Vivid
High
High
Low