42LG60 (CHASSIS:LA84B) - LG TV Service Manual (repair manual). Page 8

Read LG 42LG60 (CHASSIS:LA84B) Service Manual online

C
2008
- 8 -
Peak & average Brightness & Contrast measure standard specification
- White Peak brightness measure specification
1) In non-impressed condition, measure peak brightness displayable as much as possible LCD module. 
2) Measuring instrument: CA-110 or a sort of Color Analyzer.
3) Pattern Generator : VG-828 or a sort of digital pattern generator  (displayable Full White & 1/25 White Window pattern) 
4) Measure condition
-  Test pattern: in center, 1/5(H)x1/5(V) of Window Pattern (white pattern in non-impressed condition) 
-  SET condition : Contrast & Brightness Level 100% 
-  Environment condition : Dark room in the non outside light
-  Video menu option condition 
5) Measurement
-  Do heat-run LCD module at 30minutes in normal temperature (25°…) by using full white pattern of 15% signal level(38 gray
level). 
-  Impress test pattern signal in 1/5(H) * 1/5(V) White Window of 100%(255Gray Level) 
-  measure 3 times brightness of central white window, and mark peak brightness in max brightness degree   
-  measure the same condition in video signal /RGB signal. 
Average Brightness measure specification
1) Impress 100%(255Gray Level) full white pattern at the same peak brightness measurement. 
2) Measure average brightness in 9 points.   
Contrast ratio measure specification
1) Test display signal : 30x30 dots White Window signal & all Black Raster signal
2) Dark room measure condition : Using touch type Color analyzer CA-100 Dark room in the non outside light 
3) Bright room measure condition :  In bright room of 150Lx illumination in the panel surface, locate a source of light on the above
45°of the panel surface.
4) Measure method
- In standard test condition, impress 30x30 dots White Window Pattern signal .
Measure center peak brightness degree Lw of white window
- Impress black Raster signal as contrast ratio measurement signal.
Measure black brightness degree Lb of PDP central 
Calculate the following numerical formula.
Contrast ratio = Lw / Lb
* If it does not use Prior measurement, use generally simple test measurement. 
The Correct measure specification is followed by IEC61988-2/CD, JAPAN EIAJ-2710 
Signal 
Picture Mode 
Fresh Contrast 
Fresh Color
Black Level 
RF NTSC-M Vivid
Off 
Off 
Low 
AV NTSC-J Vivid  Off 
Off  High 
Component 720P 
Vivid 
Off 
Off 
High 
RGB 1024x768 Vivid 
Off 
 
NA 
NA 
HDMI DTV 
720P  Vivid 
Off 
Off 
Low 
1                          4                            7
2                          5                            8
3                          6                            9
Page of 44
Display

Click on the first or last page to see other 42LG60 (CHASSIS:LA84B) service manuals if exist.