37SL80YD-AA (CHASSIS:LB91T) - LG TV Service Manual (repair manual). Page 12

Read LG 37SL80YD-AA (CHASSIS:LB91T) Service Manual online

4. Total Assembly line process
4-1. Adjustment Preparation
• W/B Equipment condition
CA210 : CH 9, Test signal : Inner pattern (85IRE)
• Above 5 minutes H/run in the inner pattern. (Power on” key
of adjust remote control)
- Connecting picture of the measuring instrument 
(On Automatic control)
Inside PATTERN is used when W/B is controlled. Connect to
auto controller or push Adjustment R/C POWER-ON ->
Enter the mode of White-Balance, the pattern will come out.
* Auto-control interface and directions
1) Adjust in the place where the influx of light like floodlight
around is blocked. (illumination is less than 10ux).
2) Adhere closely the Color Analyzer (CA210) to the module
less than 10cm distance, keep it with the surface of the
Module and Color Analyzer’s Prove vertically.(80~100°).
3) Aging time
- After aging start, keep the power on (no suspension of
power supply) and heat-run over 15 minutes.
- Using ‘no signal’ or ‘full white pattern’ or the others, check
the back light on.
* Auto adjustment Map(RS-232C)
- RS-232C COMMAND
[ CMD  ID  DATA ]
Wb     00    00       White Balance Start
Wb     00     ff        White Balance End
** Caution **
Color Temperature : COOL, Medium, Warm.
One of R Gain/G Gain/ B Gain should be kept on 0xC0, and
adjust other two lower than C0.
(when R/G/B Gain are all C0, it is the FULL Dynamic Range
of Module)
* Manual W/B process using adjusts Remote control.
• After enter Service Mode by pushing “ADJ” key,
• Enter White Balance by pushing “
G
” key at “3. White
Balance”.
* After done all adjustments, Press “In-start” button and compare
Tool option and Area option value with its BOM, if it is correctly
same then unplug the AC cable.
If it is not same, then correct it same with BOM and unplug AC
cable.
For correct it to the model’s module from factory JIG model.
* Push the “IN STOP KEY” after completing the function inspection.
4-2. DDC EDID Write (RGB 128Byte )
• Connect D-sub Signal Cable to D-Sub Jack.
• Write EDID DATA to EEPROM (24C02) by using DDC2B
protocol.
• Check whether written EDID data is correct or not.
* For SVC main Ass’y, EDID have to be downloaded to Insert
Process in advance.
4-3. DDC EDID Write (HDMI 256Byte)
• Connect HDMI Signal Cable to HDMI Jack.
• Write EDID DATA to EEPROM(24C02) by using DDC2B
protocol.
• Check whether written EDID data is correct or not.
* For SVC main Ass’y, EDID have to be downloaded to Insert
Process in advance.
4-4. EDID DATA
1) All Data : HEXA Value
2) Changeable Data :
*: Serial No : Controlled / Data:01
**: Month : Controlled / Data:00
***: Year : Controlled
****: Check sum
- 12 -
EZ ADJUST
0. Tool Option1
1. Tool Option2
2. Tool Option3
3. Tool Option4
4. Country Group
5. ADC Calibration
6. White Balance
7. Test Pattern
8. EDID D/L
9. Sub B/C
10. V-Com
11. P-Gamma
White Balance
Color Temp.
R-Gain
G-Gain
B-Gain
R-Cut
G-Cut
B-Cut
Test-Pattern.
Reset
Cool
172
172
192
64
64
64
ON
To set
RS-232C COMMAND  
MIN
CENTER           
MAX
[CMD ID DATA]
(DEFAULT)
Cool Mid Warm
Cool Mid Warm
Gain
jg  Ja  jd  00 172 192 192 255
Gain
jh  Jb  je  00 172 192 192 255
Gain  ji 
Jc 
jf
00 192 192 172 255
Cut 
64 64 64 
128
Cut 
64 64 64 
128
Cut 
64 64 64 
128
Cool 13,000k
ºK
X=0.269(±0.002)
Y=0.273(±0.002)
<Test Signal>
Medium 9,300k
ºK
X=0.285(±0.002)
Inner pattern
Y=0.293(±0.002)
(216gray,85IRE)
Warm
6,500k
ºK
X=0.313(±0.002)
Y=0.329(±0.002)