37LV370S-ZB, 37LV375G-ZC, 37LV375S-ZC, 37LV375W-ZC (CHASSIS:LD12B) - LG TV Service Manual (repair manual). Page 12

Read LG 37LV370S-ZB / 37LV375G-ZC / 37LV375S-ZC / 37LV375W-ZC (CHASSIS:LD12B) Service Manual online

- 12 -
4.2.7. Edge LED White balance table
A
IOP & Edge LED module change color coordinate because
of aging time.
A
apply under the color coordinate table, for compensated
aging time.
- EDGE LED(LV3700)
4.3. EYE-Q function check
Step 1) Turn on TV
Step 2) Press EYE key of Adj. R/C
Step 3) Cover the Eye Q II sensor on the front of the using
your hand and wait for 6 seconds
Step 4) Confirm that R/G/B value is lower than 10 of the “Raw
Data (Sensor data, Back light)”. If after 6 seconds,
R/G/B value is not lower than 10, replace Eye Q II
sensor.
Step 5) Remove your hand from the Eye Q II sensor and wait
for 6 seconds.
Step 6) Confirm that “ok” pop up. If change is not seen,
replace Eye Q II sensor.
4.4. Option selection per country
(1) Overview
- Option selection is only done for models in Non-EU.
- Applied model: LD12B Chassis applied EU model.
(2) Method
1) Press ADJ key on the Adj. Remote Control, then select
Country Group Menu.
2) Depending on destination, select Country Group Code
04 or Country Group EU then on the lower Country
option, select US, CA, MX. Selection is done using +, -
or 
GF
KEY.
5. Tool Option selection
- Method : Press Adj. key on the Adj. Remote Control, then
select Tool option.
6. Ship-out mode check(In-stop)
After final inspection, press IN-STOP key of the Adj. R/C and
check that the unit goes to Stand-by mode.
7.1. Method
- Check that Power Cord is fully inserted to the SET.
(If loose, re-insert)
- Unit fully inserted Power cord, Antenna cable and A/V
arrive to the auto-check process. 
- Connect D-terminal to AV JACK TESTER
- Auto CONTROLLER(GWS103-4) ON
- Perform GND TEST
- If NG, Buzzer will sound to inform the operator.
- If OK, changeover to I/P check automatically.
(Remove CORD, A/V form AV JACK BOX)
- Perform I/P test
- If NG, Buzzer will sound to inform the operator.
- If OK, Good lamp will lit up and the stopper will allow the
pallet to move on to next process.
7.2. Checkpoint
• TEST voltage
- GND: 1.5 KV/min at 100 mA
- SIGNAL: 3 KV/min at 100 mA
• TEST time: 1 second
• TEST POINT
- GND TEST = POWER CORD GND & SIGNAL CABLE
METAL GND
NEUTRAL
• LEAKAGE CURRENT: At 0.5 mArms
GP2
Aging Time
Cool
Medium
Warm
(Min.)
X
Y
X
Y
X
Y
269
273
285
293
313
329
1
0-2
280
291
296
311
319
340
2
3-5
278
288
294
308
317
338
3
6-9
276
285
292
305
315
335
4
10-15
274
282
290
302
313
332
5
20-35
273
279
289
299
312
329
6
36-49
270
276
287
296
310
326
7
50-79
269
273
286
293
308
323
8
Over 80
269
273
285
293
308
323
Page of 74
Display

Click on the first or last page to see other 37LV370S-ZB / 37LV375G-ZC / 37LV375S-ZC / 37LV375W-ZC (CHASSIS:LD12B) service manuals if exist.