37LN548C, 37LN549C, 37LP360H, 37LP361H (CHASSIS:LD3AC) - LG TV Service Manual (repair manual). Page 13

Read LG 37LN548C / 37LN549C / 37LP360H / 37LP361H (CHASSIS:LD3AC) Service Manual online

- 13 -
* Auto-control interface and directions
(1)  Adjust in the place where the influx of light like floodlight 
around is blocked. (illumination is less than 10 lux).
(2)  Adhere closely the Color analyzer(CA210) to the module 
less than 10 cm distance, keep it with the surface of the 
Module and Color analyzer's prove vertically.(80° ~ 100°).
(3) Aging time
-  After aging start, keep the power on (no suspension of 
power supply) and heat-run over 5 minutes.
-  Using 'no signal' or 'POWER ONLY' or the others, check 
the back light on.
▪ Auto adjustment Map(using RS-232C to USB cable)
RS-232C COMMAND
[CMD  ID  DATA]
  Wb 
00  00 
White Balance Start
  Wb 
00  ff 
White Balance End
<Caution>
Color Temperature : COOL, Medium, Warm. 
One of R Gain/G Gain/ B Gain should be kept on 0xC0, and 
adjust  other  two  lower  than  C0.(When  R/G/B  Gain  are  all 
C0, it is the FULL Dynamic Range of Module)
* Manual W/B process using adjust Remote control.
▪ After enter Service Mode by pushing "ADJ" key,
▪  Enter  White  Balance  by  pushing  "►"  key  at  "8.  White 
Balance".
*  After you finished all adjustments, Press "In-start" key and 
compare Tool option and Area option value with its BOM, if 
it  is  correctly  same  then  unplug  the AC  cable.  If  it  is  not 
same, then correct it same with BOM and unplug AC cable.
For correct it to the model's module from factory Jig model.
*  Push  the  "IN  STOP"  key  after  completing  the  function 
inspection. And Mechanical Power Switch must be set “ON”.
4.5. Outgoing condition Configuration
■  When  pressing  IN-STOP  key  by  SVC  remocon,  Red  LED 
are blinked alternatively. And then automatically turn off.
(Must not AC power OFF during blinking)
5. GND and HI-POT Test
5.1. HI-POT auto-check preparation
-  Check the POWER cable and SIGNAL cable insertion condition
5.2. HI-POT auto-check
(1)  Pallet moves in the station. (POWER CORD / AV CORD is 
tightly inserted)
(2) Connect the AV JACK Tester.
(3) Controller (GWS103-4) on.
(4) HI-POT test (Auto)
- If Test is failed, Buzzer operates.
-  If Test is passed, GOOD Lamp on and move to next proc-
ess automatically.
5.3. Checkpoint
(1) Test voltage
- Touchable Metal : 3 KV / min at 100 mA
- SIGNAL : 3KV / min at 100 mA
(2) TEST time: 1 second. (case : mass production )
(3) TEST POINT
- Touchable Metal => LIVE & NEUTRAL : Touchable Metal.
- SIGNAL => LIVE & NEUTRAL : SIGNAL.
6. Model name & Serial number D/L
▪ Press "Power on" key of service remote control.
(Baud rate : 115200 bps)
▪ Connect RS232 Signal Cable to RS-232 Jack.
▪ Write Serial number
▪ Must check the serial number at the Diagnostics of SET UP menu.
  (Refer to below).
6.1. Signal Table
CMD : A0h
LENGTH : 85~94h (1~16 bytes)
ADH : EEPROM Sub Address high (00~1F)
ADL : EEPROM Sub Address low (00~FF)
Data : Write data
CS : CMD + LENGTH + ADH + ADL + Data_1 +...+ Data_n
Delay : 20ms
6.2. Command Set
* Description
FOS Default write : <7mode data> write
Vtotal,  V_Frequency,  Sync_Polarity,  Htotal,  Hstart,  Vstart,  0, 
Phase
Data write : Model Name and Serial Number write in EEPROM,.
RS-232C COMMAND
[CMD ID DATA]
MIN
CENTER
(DEFAULT)
MAX
Cool
Mid
Warm
Cool Mid Warm
R Gain
jg
Ja
jd
00
172
192
192
192
G Gain
jh
Jb
je
00
172
192
192
192
B Gain
ji
Jc
jf
00
192
192
172
192
R Cut
64
64
64
128
G Cut
64
64
64
128
B Cut
64
64
64
128
EZ ADJUST
0. Tool Option1
1. Tool Option2
2. Tool Option3
3. Tool Option4
4. Tool Option5
5. Commercial Tool Option
6. Country Group
7. ADC Calibration
8. White Balance
 
9. 10 Point WB
10. Test Pattern
11. EDID D/L
12. Sub B/C
13. Ext. Input Adjust 
Whit Balance
Color Temp. 
 
R-Gain
G-Gain
B-Gain
R-Cut
G-Cut
B-Cut
Test-Pattern
Backlight
Reset 
      To Set
Cool
172
172
192
64
64
64
ON
100
CMD
LENGTH
ADH
ADL
DATA_1
. . .
Data_n
CS
DELAY
Adjust mode
CMD(hex)
LENGTH(hex)
Description
EEPROM WRITE
A0h
84h+n
n-bytes Write (n = 1~16)
Page of 38
Display