32LS3500, 32LS350Y, 32LS3590, 32LS3700 (CHASSIS:LB21C) - LG TV Service Manual (repair manual). Page 11

Read LG 32LS3500 / 32LS350Y / 32LS3590 / 32LS3700 (CHASSIS:LB21C) Service Manual online

- 11 -
3.3. LAN Inspection
3.3.1. Equipment & Condition
▪ Each other connection to LAN Port of IP Hub and Jig
3.3.2. LAN inspection solution
▪ LAN Port connection with PCB
▪ Network setting at MENU Mode of TV
▪ Setting automatic IP
▪ Setting state confirmation
->  If  automatic  setting  is  finished,  you  confirm  IP  and  MAC 
Address.
3.4. LAN PORT INSPECTION(PING TEST)
Connect SET -> LAN port == PC -> LAN Port
3.4.1. Equipment setting
(1) Play the LAN Port Test PROGRAM.
(2) Input IP set up for an inspection to Test Program.
*IP Number : 12.12.2.2
3.4.2. LAN PORT inspection (PING TEST)
(1) Play the LAN Port Test Program.
(2) Connect each other LAN Port Jack.
(3) Play Test (F9) button and confirm OK Message.
(4) Remove LAN cable.
3.5. Function Check
* Check display and sound
- Check Input and Signal items. (cf. work instructions)
1) TV
2) AV 
3) COMPONENT (480i)
4) RGB (PC : 1024 x 768 @ 60hz)
5) HDMI
* Display and Sound check is executed by Remote control.
<Caution> 
Not to push the INSTOP key after completion if the function 
inspection.
4. Total Assembly line process
4.1. Adjustment Preparation
▪ W/B Equipment condition
CA210
: CCFL/EEFL -> CH9, Test signal: Inner pattern(80IRE)
  LED -> CH14, Test signal: Inner pattern(80IRE)
▪  Above 5 minutes H/run in the inner pattern. ("power on" key 
of Adjustment remote control)(Only EEFL)
▪  Edge  LED  W/B Table  in  process  of  aging  time  (Only  LGD 
Edge LED Module except AUO, CMI, IPS Module)
*  Connecting picture of the measuring instrument
(On Automatic control)
Inside PATTERN is used when W/B is controlled. Connect to 
auto controller or push Adjustment R/C POWER ON -> Enter 
the mode of White-Balance, the pattern will come out.
* Auto-control interface and directions
(1)  Adjust in the place where the influx of light like floodlight 
around is blocked. (illumination is less than 10 lux).
(2)  Adhere closely the Color analyzer(CA210) to the module 
less than 10 cm distance, keep it with the surface of the 
Module and Color analyzer's prove vertically.(80° ~ 100°).
(3) Aging time
-  After aging start, keep the power on (no suspension of 
power supply) and heat-run over 5 minutes.
-  Using 'no signal' or 'POWER ONLY' or the others, check 
the back light on.
Full White Pattern
CA-210
COLOR
ANALYZER
TYPE : CA-210
RS-232C Communication
SET
PC
Cool
13,000 K X=0.269 (±0.002)
Y=0.273 (±0.002)
<Test Signal>
Inner pattern
(204gray,80IRE)
Medium
9,300 K X=0.285 (±0.002)
Y=0.293 (±0.002)
Warm
6,500 K X=0.313 (±0.002)
Y=0.329 (±0.002)
S7LR2
Aging 
time
(Min)
Cool
Medium
Warm
X
y
x
y
x
y
269
273
285
293
313
329
1
0-2
280
287
296
307
320
337
2
3-5
279
285
295
305
319
335
3
6-9
277
284
293
304
317
334
4
10-19
276
283
292
303
316
333
5
20-35
274
280
290
300
314
330
6
36-49
272
277
288
297
312
327
7
50-79
271
275
287
295
311
325
8
80-119
270
274
286
294
310
324
9
Over 120
269
273
285
293
309
323
Page of 42