32LG700H (CHASSIS:LA80A) - LG TV Service Manual (repair manual). Page 11

Read LG 32LG700H (CHASSIS:LA80A) Service Manual online

- 11 -
5. Adjustment of ADC on PCB Ass’y
Level
5.1. Method of adjustment through RS-232C
- System control RS-232 Host should be “PC” for adjustment.
Refer to the “6.1.2 Procedure of Adjustment” and adjust
three items of ADC on PCB Ass’y level through the RS-
232C.
** ADC adjustment RS232C Protocol Ver 1.0
* Baud Rate : 115,200 bps
* RS232C Host : PC
* echo : None
(1) Requirement for Adjustment
- Pattern Generator : MSPG-925FA
- Adjust 480i Comp1(Model : 209, Pattern : 65)
- Adjust 1080p Comp1 / RGB(Model : 225, Pattern : 65)
(2) Adjustment Procedure
- ad 00 00  Entering ADC Adjustment Mode
- kb 00 04  Component1 Input Change
- ad 00 10  Adjust 480i Comp1
- kb 00 06  RGB-DTV Input Change
- ad 00 10  Adjust 1080p Comp1/RGB
- ad 00 90  Finish adjustment
5.2. MAC Address Download
For downloading the MAC address which be allotted on each
LAN Card.
(1) Adjustment Method
1) Connecting the TV set and the PC which has MAC
Address Writing program through the RS232C cable.
2) Editing the mac address.txt
(Inserting start MAC address at top low.
Inserting start MAC address at bottom low.
Launch MAC Address Writing program and set just like
below picture. - (1)
3) Click the LOAD button for reading the MAC address.- (2)
(SAVE : Saving the current MAC Address
CLEAR : Initializing the space which insert MAC Address.
4) Click the “MAC Address writing” button to write current
MAC Address.- (3)
5) In case of being downloaded normally, you can see the
“OK” message in the window. - (4)
6) In case of being downloaded normally, MAC address
increased one by one automatically. So the next set, just
click the “MAC Address writing” button after connecting
the port.
(Whenever be finished, the program saves the MAC
Address in “mac address.txt” file automatically.)
5.3. PING Test
* For confirm works normally the LAN card through PING TEST.
(1) Adjustment Method (PCB Ass’y Level)
1) Connecting the LAN to Ass’y and then turn on the Power.
(Default IP Setting is “Automatic setting” and allocated
the IP from Router each Power ON time automatically.)
2) Press the ADJ Key in the adjustment remote controller.
3) Press the “11. ACAP PING TEST” in EZ ADJUST menu
to check the Network works well. 
In case of normal status, you can see the “Network is
normal” message. 
And abnormal case, you can see “Network is not normal”
message.
480i Component
1080p Component / RGB
MSPG-925FA
Model No : 209
Pattern No : 65
Model No : 225
Pattern No : 65
Procedure
Command
Set Act
1. Entering ADC mode ad 00 00 d 00 OK00x
2. Input change
kb 00 01
b 00 OK01x (Adjust RF and Video)
kb 00 04
b 00 OK04x (Adjust 480i Comp1)
kb 00 06  b 00 OK06x (Adjust 1080p Comp1/RGB)
3. Start ADC
ad 00 10
4. Result return
OKx (Success)
NGx ( Fail )
5. Data read
( main)
(main)
ad 00 20 000000000000000000000000007c007b006dx
( sub )
(Sub)
ad 00 21 000000070000000000000000007c00830077x
6. Data confirm
ad 00 99 NG 03 00x (Fail)
NG 03 01x (Fail)
NG 03 02x (Fail)
OK 03 03x (Success)
7. Finish ADC
ad 00 90 d 00 OK90x
 
( 1) 
(2) 
(3) 
(4) 
Page of 41
Display