7. ADC Calibration
<Caution>
- System control RS-232 Host should be “PC” for adjustment.
- Before AV ADC Calibration, execute the “Module selection”.
7.1. Adjustment of RF/AV/S-VIDEO
(1) Required Equipments
- Remote controller for adjustment
- MSPG-925FS Pattern Generator (Which has Video
Signal: 7 Color Bar Pattern shown in Fig. 1)
=> Model: 202 / Pattern: 65
(2) Method of Auto RF/AV/S-VIDEO Color Balance.
1) Input the Video Signal : 7 Color Bar signal into AV3.
2) Set the PSM to Dynamic mode in the Picture menu.
3) Press ADJ key on R/C for adjustment.
4) Press the 
G
(Vol.+) key to operate the set, then it
becomes automatically.
5) On bottom side of OSD, “AV OK” means the adjustment
is completed.
7.2. Adjustment of Component
(1) Required Equipments
- Remote controller for adjustment
- MSPG-925FS Pattern Generator (Which has 720p/50Hz
YPbPr output Pattern shown in Fig.1)
=> Model:215/Pattern: 65
(2) Method of Auto Component Color Balance
1) Input the Component 720p/50Hz 7 Color Bar(MSPG-
925FS model:215, pattern:65) signal into Component.
2) Set the PSM to Dynamic mode in the Picture menu.
3) Press the ADJ key on R/C for adjustment.
4) Press the 
G
(Vol.+) key to operate the set , then it
becomes automatically.
5) On bottom side of OSD, “Component OK” means the
adjustment is completed.
7.3. Adjustment of RGB
(1) Required Equipments
- Remote controller for adjustment
- MSPG-925F Pattern Generator (Which has XGA
[1024*768] 60Hz 8color bar 100% pattern shown in Fig.1)
(2) Method of Auto RGB Color Balance
1) Input the PC 1024x768@60Hz 100% Color Bar pattern
(MSPG-925F model:65, pattern:60) into RGB. 
(Using D-sub to D-sub cable)
2) Set the PSM to Dynamic mode in Picture menu.
3) Press the IN-START key on R/C for adjustment
4) Press the 
G
(Vol.+) key operate To set , then it becomes
automatically.
5) On bottom side of OSD, “RGB OK” means the
adjustment is completed.
* Before White-balance, the AV ADC should be done.
8. White Balance
* Test Equipment
Color Analyzer (CA-210/CH.9)
-> When you adjust LCD color temperature, on Color
analyzer (CA-210), you should use Channel 9 which is
Matrix compensated (White, Red, Green, Blue revised) by
CS-1000 and adjust in accordance with White balance
adjustment coordinate which is specified on the next.
* Color temperature standards according to CSM and Module
Cool : 11,000k
Medium : 9,300k
Warm : 6,500k
* White balance adjustment coordinate and color temperature
- PC (for communication through RS-232C)
-> UART Baud rate : 115200 bps
- Luminance Y AV : upper 200 cd/m
2
≥ (Typ : 350 cd/m
2
)
-> Applying to Cool, Medium, Warm mode
* Connecting picture of  the measuring instrument (On
Automatic control )
Inside PATTERN is used when W/B is controlled. Connect to
auto controller or push control R/C IN-START -> Enter the
mode of White-Balance, the pattern will come out.
* Measurement color analyzer : CS1000 or CA210(CH 9)
- 12 -
ADC
RF/AV/S-VIDEO
Component
RGB-PC
MSPG925FS PALJ
Model:215 (720P)
Model: 60
INPUT SELECT       AV3
Pattern:65
(1024*768 60Hz)
Model: 202 (PAL-BGDHI) * 720P/50Hz 
Pattern: 65
Pattern: 65
7 Color Bar
* PAL 7 Color Bar
Cool
CS-1000
CA-210(CH 9)
x
0.276
0.276±0.002
y
0.283
0.283±0.002
∆uv
0.000
0.000
Medium
CS-1000
CA-210(CH 9)
x
0.285
0.285±0.002
y
0.293
0.293±0.002
∆uv
0.000
0.000
Warm
CS-1000
CA-210(CH 9)
x
0.313
0.313±0.002
y
0.329
0.329±0.002
∆uv
0.004
0.004
<Fig. 2> Connecting picture (On Automatic Control)