32LG40 (CHASSIS:LA89D) - LG TV Service Manual (repair manual). Page 14

Read LG 32LG40 (CHASSIS:LA89D) Service Manual online

- 14 -
5-6. Reference 
(1) Brightness : Full white 216 Gray 
(2) Standard color coordinate and white balance when using
the CS-1000
(3) Standard color coordinate and white balance when using
the CA-210 (CH 10)
6. HDCP (High-Bandwidth Digital
Contents Protection) SETTING
- Set write size to 64 bytes
- Set delay time to 250ms
- Connect D-sub Signal Cable to D-Sub Jack
- Input HDCP key with HDCP-key- in-program
- HDCP Key value is stored on EEPROM(AT24C512) which is
80~A1 addresses of  0xA0~0xA2 page
- AC off/ on and on HDCP button of MSPG925 and confirm
whether picture is displayed or not of using MSPG925
- HDCP Key value is different among the sets. 
7. Select the option by country
7-1. Overview
model only, which selects the rating related country.
2) Applied models: LA89D Chassis applied None USA
Model(Canada, Mexico)
7-2. How to select  
1) Press the In-Start key of the R/C and press the red oval
OP1(PIP CH-) key to enter into the Factory Option menu.
2) Select 1.USA, 2.CANADA or 3.MEXICO from the country
select according to the destination. At this time, use the
volume +/- key to adjust 
7-3. Set the shipping mode (In-stop)
- After completing the final test, in order to set the set to the
shipping condition, press the In-Stop key of the R/C to make
sure that the set is turned off.
8. GND and resisting pressure test
8-1. How to test
(1) Preparing for the automatic test on the GND & resisting
pressure 
- Make sure that the power cord is inserted into the set
completely. (When it is disconnected or loosened, test
after inserting it)
(2) Perform the automatic test on the GND & resisting pressure
1) The set with power cord, the cord and the A/V
completely inserted into the tuner is loaded on the pallet
and entered into the automatic test process.
2) Connect the D-terminal AV JACK tester
3) Turn on the automatic (GWS103-4)
4) Perform the GND TEST
5) If it is not good, the buzzer is operated to notify the test
result to the operator.
6) If it is OK, it is automatically switched to the resisting
pressure test. (Disconnect the cord and the A/V from the
AV JACK BOX)
6) Perform the resisting pressure test
7) If it is not good, the buzzer is operated to notify the test
result to the operator.
8) If it is OK, the GOOD LAMP is turned and the stopper is
moves down, and it moves to the next process.
8-2. Items to manage
(1) TEST voltage
- GND : 1.5KV/min at 100mA
- SIGNAL : 3KV/min at 100mA
(2) TEST time:1 second
(3) TEST POINT
- GND test = between Power cord GND and Signal cable
metal GND
- Resisting pressure test = between Power cord GND and
Live & Neutral
(4) LEAKAGE CURRENT: Set to 0.5mArms 
Mode
Color Coordination
Temp
∆UV
x
y
COOL
0.276
0.283
11000K
0.0000
MEDIUM
0.285
0.293
9300K
0.0000
WARM
0.313
0.324
6500K
0.0000
Mode
Color Coordination
Temp
∆UV
x
y
COOL
0.276±0.002
0.283±0.002
11000K
0.0000
MEDIUM
0.285±0.002
0.293±0.002
9300K
0.0000
WARM
0.313+0.002
0.324±0.002
6500K
0.0000
Page of 45