1. Application range
This spec sheet is applied all of the 32/42/47/55LD520-UA
LCD TV with LA01B chassis. 
2. Requirement for Test
Each part is tested as below without special appointment.
1) Temperature:  25±5ºC, (77°±9ºF), CST: 40±5°C 
2) Relative Humidity:  65±10%
3) Power Voltage : Standard input voltage(100-240V~, 50/60Hz)
* Standard Voltage of each product is marked by models
4) Specification and performance of each parts are followed
each drawing and specification by part number in
accordance with BOM.
5) The receiver must be operated for about 20 minutes prior to
the adjustment.
3. Test method
1) Performance: LGE TV test method followed 
2) Demanded other specification 
- Safety : UL, CSA, IEC specification 
- EMC: FCC, ICES, IEC specification 
Model
Market
Appliance
32LD520-UA 
Safety : UL1492, CSA C22.2.No.1, 
42LD520-UA 
EMC : FCC Class B, IEC Class B 
47LD520-UA
55LD520-UA
- 6 -
SPECIFICATION
NOTE : Specifications and others are subject to change without notice for improvement.
4. General Specification(TV)
No
Item
Specification
Remark
1
Receivable System
1) ATSC / NTSC-M
2
Available Channel
VHF : 02 ~ 13
UHF : 14 ~ 69
DTV : 02 ~ 69
CATV : 01 ~ 135
CADTV : 01 ~ 135
3
Input Voltage
1) AC 100 ~ 240V 50/60Hz
4
Market
5
Screen Size
32 inch
FHD  
32LD520-UA 
42 inch 
FHD  
42LD520-UA 
47 inch 
FHD  
47LD520-UA 
55 inch 
FHD  
55LD520-UA 
6
Aspect Ratio
16:9
7
Tuning System
FS
8
LCD Module
T546HW01 
AUO  
55LD520-UA 
LC470WUH-SCA1 LGD 
 
47LD520-UA
LC420WUH-SCA1 LGD 
 
42LD520-UA
LC320WUH-SCA1 LGD 
 
32LD520-UA
9
Operating Environment
Temp  : 0 ~ 40 deg
Humidity : ~ 80 %
10
Storage Environment
Temp  : -20 ~ 60 deg
Humidity : -85 %